8.3
Definitions of indicators in the
display
Symbol
Explanation
Error message available.
Warning message available.
Maintenance signal is transmitted.
Measuring range of analog interface
exceeded.
Measurement value less than range of
analog interface.
®
HART
operation is active. Analog inter-
face is set to a fixed value and is not trans-
mitting any measurement signal.
SIL
SIL operation mode is activated.
®
8.3.1 Polytron
8100 EC-specific indicators in
the display
Symbol
Explanation
"Preventive" maintenance: The sensor is
ready for operation.
"Preventive" maintenance: The sensor is
ready for operation but is close to the end
of its life cycle.
"Preventive" maintenance: The sensor is
still ready for operation but should be
changed as soon as possible.
The data logger is active in Roll mode.
The data logger is active in stack mode.
8.4

User interface keys

The instrument is designed for the magnetic wand (part
number 4544101: blue body, white logo) to be used with the
enclosure lid in place. If the enclosure lid is not in place, the
magnetic wand may activate two or more buttons at once
(cross-talk).

Button Function

Upwards / Function key
Downwards / Menu key
M
Different functions depending on the type of menu
OK
Dräger Polytron
®
8000 Series
8.5

Info mode and function key

8.5.1 Activating info mode
The Info mode is used to show instrument relevant
information. This does not interrupt the normal operation of
the instrument.
● Tap and hold
for 3 seconds in measuring mode.
8.5.2 Info mode navigation
Button Function
Switches to the next screen
Switches to the previous screen
M
Ends info mode
OK
If no key is tapped within 30 seconds, the instrument will
automatically return to normal operation.
8.5.3 Using function key
Using the function key, a pre-set function can be executed. By
default the faults are displayed.
● Tap and hold
for 1 seconds in measuring mode.
To configure the function key, see 12.4 Configuring function
key.
8.6
Menu
8.6.1 Menu navigation
Button Function
Scrolls upwards.
Sets values.
Scrolls downwards.
M
Sets values.
Confirms entry.
OK
Selects menus and functions.
8.6.2 Passwords
Calibration
Access to information (Information menu)
PWD
and calibration settings (Calibration
menu)
Default: _ _ _ 1
Settings PWD
Access to all configurations and menus
Default: _ _ _ 2
To change passwords, see 12.1.
8.6.3 Entering the menu
● To directly enter the Information menu:
a. Tap and hold
for 1 second in the measuring mode.
M
● To enter the Calibration menu:
a. Tap and hold
for 3 seconds in measuring mode
M
b. Select Enter password
c. Enter Calibration PWD.