17.2 Signal transmission to control unit

The measuring range and performance characteristics
depend on the installed sensor (see the Instructions for Use
and/or data sheet for the installed sensors).
Frequency of measurement calculation: 1 x per second
(update of display, analog interface and relays).
Analog signal
Normal operation
Drift below zero
Measuring range
exceeded
Instrument fault
Fault on analog
interface
Maintenance signal
Impedance of the signal loop
Operating
Impedance
mode
range of the
signal loop
Operation
0 to 230 Ω
without
Rising linearly
®
HART
com-
with the supply
munication
voltage from:
0 to 230 Ω at 10
V to
0 to 500 Ω at 16
V
0 to 500 Ω
Measuring range
1)
0 to 10,000 ppm
1)
0 to 100 %LEL,
1)
0 to 5 Vol%,
For CH4 (Methane) 0 to 100
1)
Vol%
1)
0 to 10,000 ppm
1)
0 to 100 %LEL
1)
0 to 5 Vol%
1)
0 to 100 Vol%
4 ... 20 mA
3,8 ... 4 mA
20 ... 20,5 mA
≤ 1.2 mA
> 21 mA
3.4 mA steady signal or 1 Hz mod-
ulation between 3 and 5 mA
(selectable)
Supply voltage range
at 10 V DC
10 to 18 V DC
18 to 30 V DC
Operating
Impedance
mode
range of the
signal loop
Operation
230 to 270 Ω
®
with HART
Rising linearly
communica-
with the supply
tion
voltage from:
230 to 270 Ω at
11 V to
230 to 500 Ω at
16 V
230 to 500 Ω
230 to 500 Ω
®
HART
Mul-
tidrop opera-
tion
For further information regarding the fieldbus interface
installation consult the corresponding Technical Hanbook.

17.3 Cable specifications

For non-conduit installations, use shielded cables.
®
Analog and HART
connection with control unit and
power supply
Power supply and
signals
Relays
Digital connection with control unit
Instruments with fieldbus interfaces and remote sensors
must be installed with shielded cables.
Modbus RTU
®
PROFIBUS
PA
TM
Foundation
Field-
bus
Power supply

17.4 Power supply and relays

1)
Relay rating
2)
SPDT
230 V
30 V
, resistive
load
1) For safety-related applications (SIL 2), the maximum contact rating is
®
reduced (see Polytron
8xx0 Safety Manual).
2) Single pole, double throw, (changeover electrical contacts)
Supply voltage range
at 13 V DC
11 to 16 V DC
18 to 30 V DC
10 to 30 V DC
3-core shielded cable
24 - 12 AWG / 0.2 - 2.5 mm²
20 - 12 AWG / 0.5 - 2.5 mm²
4-core, ≥ AWG 26
2-core, Cable type A
Wave impedance R
:135 - 165 Ω
w
Capacitance / unit length C':<
30 pF/m
Loop resistance R':110 Ω/km
Core diameter d:0.64 mm
Core cross section q:> 0.34 mm²
Shield coverage:> 90 %
24 - 12 AWG / 0.2 - 2.5 mm²
0.1 A - 5 A
0.1 A (minimum) - 5 A
®