Tabla6-6. Continuación - Read mode, parámetros del sistema de comparación de carga RFL 9300 para tres terminales
83
R2 FD PH
84
R2 FD GD
85
R2 BCKUP
86
R2 PH OC
87
R2 GD OC
88
R2 P TOC
89
R2 PPKUP
90
R2 PCURV
91
R2 PDIAL
92
R2 G TOC
93
R2 GPKUP
94
R2 GCURV
95
R2 GDIAL
96
R2 OH/UG
97
R2 OP/CN
98
R2 STUB
100
R2 GD TP
101
R2 PNGPG
103
SWID CC1
104
SWID CC2
105
SWID SV
106
SWID PCA
107
SWID PCB
108
SWID PCC
109
SWID PCG
110
SWID DC
111
EXIT
140
SGL POLE
141
SEL POLE
145
TRIP RLS
160
RS1 POLE
161
R1 SEL P
165
TRP RLS 1
180
RS2 POLE
181
R2 SEL P
185
TRP RLS 2
RFL 9300
30 de enero de 2002
B e c a u s e R F L ™ a n d H u b b e l l ® h a v e a p o l i c y o f c o n t i n u o u s p r o d u c t i mp r o v e me n t , we r e s e r v e t h e r i g h t t o c h a n g e d e s i g n s a n d s p e c i fi c a t i o n s wi t h o u t n o t i c e .
Remote 2 fault detector phase current.
Remote 2 fault detector ground current.
Remote 2 backup functions.
Remote 2 phase overcurrent backup.
Remote 2 ground overcurrent backup.
Remote 2 phase inverse time-overcurrent backup.
Remote 2 phase inverse time-overcurrent pickup value.
Remote 2 phase inverse time-overcurrent curve select value.
Remote 2 phase inverse time-overcurrent dial setting value.
Remote 2 ground inverse time-overcurrent backup.
Remote 2 ground inverse time-overcurrent pickup value.
Remote 2 ground inverse time-overcurrent curve select value.
Remote 2 ground inverse time-overcurrent dial setting value.
Remote 2 overhead or underground.
Remote 2 open conductor action. (7)
Remote 2 stub bus action.
Remote 2 guard before trip
Remote 2 ping-pong (round-trip delay).
Software version number for local communications controller in two-terminal systems.
Software version number for second local communications controller in three-terminal systems.
Software version number for local supervisor module.
Software version number for local Phase Controller "A" module.
Software version number for local Phase Controller "B" module.
Software version number for local Phase Controller "C" module.
Software version number for local Phase Controller "G" module.
Software version number for local display module.
Exit to STANDBY mode. Same as parameter #0. (1)
Single-Pole trip – active/inactive
Enable/Disable Selective pole relaying – Programmable; see table 6-9 for more information (8)
Trip release codes – Programmable; see table 6-9 for more information
Remote 1 single-pole trip – active/inactive
Remote 1 Selective pole relaying
Remote 1 Trip release codes
Remote 2 single-pole trip – active/inactive
Remote 2 Selective pole relaying
Remote 2 Trip release codes
>> refiérase a la pagina 6-24 para las notas <<
6-23