Electrical Connection; 3-Pin Sensors; 4-Pin Sensors With Io-Link; Wiring Diagrams For The Various Versions - Balluff BMF 415KW-HA Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 101
BMF 415KW-HA _ _ _ -W-5- _ _ -...
Magnetic Field Sensors
4
Installation and connection (continued)
4.3

Electrical connection

The sensor features overload protection.
After the overload is eliminated, the sensor is
once again functional. In addition the sensor is
reverse polarity protected and protected against
unintended miswiring.
4.3.1

3-pin sensors

S49
M8, normally open
Fig. 4-5:
Pin assignments for connector (pin side view)
Pin
Wire color
Signal
Pin 1 Brown
UB+ (operating voltage, +24 V)
Pin 3 Blue
UB– (operating voltage, GND/0 V)
Pin 4 Black
OUT1 (switching output)
Tab. 4-1:
Pin assignment
4.3.2

4-pin sensors with IO-Link

S75
M8, IO-Link, Class A
Fig. 4-6:
Pin assignments for connector (pin side view)
Pin
Wire color
Signal
Pin 1 Brown
UB+ (operating voltage, +24 V)
Pin 2 White
not connected or not present
Pin 3 Blue
UB– (operating voltage, GND/0 V)
Pin 4 Black
OUT1 (switching output) or
C/Q for IO-Link, configurable
Tab. 4-2:
Pin assignment
10
english
S4
M12, normally open
S4
M12, IO-Link, Class A
4.3.3

Wiring diagrams for the various versions

Cable versions:
BMF 415KW-HAPS-...
BN
M
BK
BU
BMF 415KW-HANS-...
BN
M
BK
BU
BMF 415KW-HAKKI-...
BN
M
BK
BU
Connector versions:
BMF 415KW-HAPS-...
1
M
4
3
BMF 415KW-HANS-...
1
M
4
3
BMF 415KW-HAKKI-...-S75-00,3 / S4-00,3
1
M
4
2
3
+
+
+
S1/IO-Link
+
+
+
S1/IO-Link
nc