Donning And Use - MSA AUER S-Cap-Air Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3

Donning and Use

1
Remove the S-Cap-Air from
its stowage. Put your head
through the neck strap.
4
Check the indicator in the
visor.
GREEN : OK
RED:
End Of Duration
Note!
When the cylinder is almost empty the green warning disc, visible inside the hood, will change to red,
CO
will start to increase and the hood must be removed.
2
Once the S-Cap-Air has been used it must be returned for servicing and maintenance, including
recharging, by trained personnel.
10
2
Hold the bag, not the cylinder
valve, pull the firing strap up-
wards.
Listen
for
airflow.
Check that the firing pin is
fully withdrawn.
If the firing pin is still in place,
access the valve and un-
screw the cap completely.
SAFETY WARNING!:
Duration
of
apparatus
starts now.
This action has started the
airflow.
5
Tighten waist belt.
3
Insert hands into the neck
seal opening and pull the
hood over the head. Adjust
inner mask and neck seal to
seal. Ensure that hair / cloth-
ing is not trapped under the
neck seal.
6
Make your escape from the
area. Do not remove hood
until well clear of danger.