Guarantee Conditions - Pontec PondoClear Set 4000 Instrucciones De Uso

Ocultar thumbs Ver también para PondoClear Set 4000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30
Open and clean the UVC water housing
How to proceed:
 J
1. Press on the engagement lug at the unit head, then turn the UVC water housing counter-clockwise against the stop.
2. Carefully remove the water housing from the unit head.
3. Clean the water housing under running water. (Not shown)
4. Clean the quartz glass outer face with a moist cloth and check for damage. (Not shown)
5. Check the O ring at the unit head for damage.
Close the UVC water housing
How to proceed:
 K
1. Carefully push the UVC water housing onto the unit head such that tenon and groove of the bayonet closure en-
gage.
2. Turn the UVC water housing clockwise against the stop and allow to engage.
Replacing the UVC lamp
Replace the UVC lamp after max. 8000 operating hours.
 To replace the UVC lamp, remove the UVC clarifying unit and refit after completion of the work. ( Cleaning the UVC
clarifying unit)
 Ensure that the identification and capacity data of the lamps used correspond to the information on the unit type plate.
( Technical data)
 Prior to inserting the UVC lamp, check the quartz glass and O ring for damage and replace if necessary.
How to proceed:
 L
1. Turn out the self-tapping screw once you have removed the UVC water housing.
2. Turn the union nut off the unit head by turning counter-clockwise.
3. Pull off the quartz glass and the O-ring while slightly turning the unit head.
4. Pull out the UVC lamp and replace.
5. Insert the quartz glass including the O ring against the stop in the unit head.
6. Tighten the clamping screw clockwise up to the stop.
7. Turn in and tighten the self-tapping screw.
8. Close the UVC water housing. ( Cleaning the UVC clarifying unit)
Storage/overwintering
Take the unit out of operation at water temperatures below +4 °C or, at the latest, when freezing temperatures are to
be expected.
 Drain the unit as far as possible, clean thoroughly and check for damage.
 Empty all hoses, pipes and connections as far as possible.
Disposal
Support us in our endeavour to keep our environment intact, and adhere to the following disposal information!
Disposal
Dispose of the unit in accordance with the national legal regulations. The UVC lamp needs special disposal. Ask your
specialist dealer.
Foam filters and seals no longer used can be disposed of with the household waste.

Guarantee conditions

PfG grants a 2 year guarantee from the date of sale on proven material and manufacturing faults. Prerequisite for our
guarantee is the presentation of the purchase receipt. Our guarantee will become null and void if the unit is misused,
electrically or mechanically damaged by inappropriate use and improper repair by non-authorised workshops. Repairs
are reserved for workshops authorised by PfG or by PfG itself. In the case of warranty claims, please return the defec-
tive unit or part freight paid to PfG together with a description of the fault and the purchase receipt. PfG reserves the
right to invoice repair costs. PfG is not liable for transport damage. Any damage must be claimed against the carrier.
Further claims of whatever type, especially consequential damage, are excluded. This guarantee does not affect the
final customer's claims against the dealer.
- EN -
17

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pondoclear set4000

Tabla de contenido