For maintenance, use only the spare parts specified. The manufacturer cannot be held liable
for any accident that occurs following a repair not performed by its customer service department
or by an approved repairer.

6.1. SERvICING

6.1.1. BATTERY RECHARGE
If the
symbol is displayed, the battery must be recharged. Connect the instrument to line power
using the mains lead; it starts charging automatically and the
bAt on the small display unit and chrG on the main display unit means fast charging in progress.
bAt on the small display unit and chrG flashing on the main display unit means that slow charging
is in progress
bAt on the small display unit and FULL on the main display unit means that charging is over.
The battery must be replaced by Manumesure or by a repairer approved by CHAUvIN
ARNOUx.
6.1.2. REPLACEMENT OF THE FUSE
If FUSE -G- appears on the display. Ensure the instrument is disconnected from any source (both test
leads and mains lead) the instrument is switched off and replace the fuse located on the front panel.
For your safety, replace a defective fuse with only a fuse having strictly identical characteristics:
Exact type of fuse (entered on the label on the front panel): FF - 0.1 A - 380 V - 5 x 20 mm - 10 kA.
Note: This fuse is in series with a 0.5 A / 3 kV internal fuse active only in case of major fault in the unit.
If after changing the fuse on the front panel, the display still indicates FUSE - G -, the unit must
be returned for servicing (see § 6.3)
6.1.3. CLEANING
Disconnect the unit completely and turn the rotary switch to OFF.
Use a soft cloth, dampened with soapy water. Rinse with a damp cloth and dry rapidly with a dry cloth
or forced air. Do not use alcohol, solvents, or hydrocarbons.
6.1.4. STORAGE
If the instrument has been left unused for an extended period (more than two months), fully charge the
battery before using.