B Standard Twin Burner Models
(models with lift-up cooktops)
1, Lift the cooktop.
2. Lift
the
burner
assemblies
straight
up and
set aside
to gain
access
to
sur-
face
burner
spuds°
3. With
a
7mm,
5/t6"
or a small
adjustable
wrench
(depend-
ing
on the
size
needed),
remove each of the four spuds on the sur-
face burner gas inlet tubes and replace
them with
the correct
gas spuds
mounted
in a holder
at the
right rear of the range, above the regulator_ Natural
gas spuds
are brass and LP gas spuds
are red or
silver. (Mount the spuds that you removed
from the
inlet tubes back in the holder°) To prevent
leakage,
make
sure
spuds
are securely
screwed
into gas
inlet tubes_
4. Replace the burner assemblies,
5. Keep all spuds with your range so you have them if
you move or get a different
gas hook-up.
Top Burner
Orifice
Drill Size
Color
Natural
Gas
#54 (_0550 Diao)
Brass
LP (Propane)
#66 (_0330 Dial)
Red or Silver
Step
3
Convert the Oven Burner Orifices
Oven Burner
1. Remove
oven door, storage drawer or broiler draw-
er and oven bottom.
The lower burner orifice spud
is located behind the storage
drawer, broiler drawer
or kick panel.
(On some
models,
a metal
shield
must be removed
to access the orifice.)
2. To convert
to LP gas, use a
1/2" wrench
to turn the lower
burner
orifice
spud
clockwise_
Tighten
the spud only until it is
snug° To prevent
damage,
do
not overtighten
the spud.
To convert
to
natural
gas,
loosen the spud about 2 turns°
Broil Burner
(on some models)
To convert
to LP gas, use a 1/2" wrench
to turn the
upper
burner
orifice
spud
clockwise°
Tighten
spud
only until it is snug with the base, To prevent
damage,
do not overtighten
spud.
To convert
to natural
gas,
loosen
the spud
about
2 turns,
Step 4
Convert Air Adjustment Shutter(s)
head screw and rotate the shut-
ter to the full open position.
With
baffle
in place,
flames
should
have approximately
1" (2°5 cm)
Screw
blue
cones
and
should
not
Air
extend beyond
the edges of the
Shutter
burner
baffle.
After 30 seconds
_-
of burner
operation,
check
for
flames
lifting
off burner
ports. If lifting
is observed,
gradually
reduce
air shutter
opening
until flames
are
stabilized.
For
natural
gas,
the shutter
should
be open
1/2"
(1.3 cm) or about 3/4 of the way open.