Set the gas quantity with the setting screw 66 of the
pressure reducer.
9 The gas quantity is indicated on the flow meter 63.
Rule of thumb:
Gas nozzle size = litres/min.
The cylinder content is indicated on the content ma-
nometer 62.
14
Starting up Handy 160 ControlPro
Abb. 7:
Control console Handy 160 ControlPro
LED malfunction
15
lights up permanently,
7-segment-display 15 shows error code.
7-Segment-display
16
displays the selected current. Alternating display
of code and set value by activated secondary
parameters.
LED Electrode
17
lights up if electrode mode is selected.
- 30 -
15
16
Starting up Handy 160 ControlPro
17 18
20
19
LED TIG
18
lights up if TIG mode is selected.
Key button electrode/TIG
19
for the selection of electrode or TIG mode as
well as secondary parameters.
Turning knob
20
for welding current adjustment for the stepless
setting of welding current.