SATA jet 3000 B RP Instrucciones De Servicio página 111

Ocultar thumbs Ver también para jet 3000 B RP:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 123
<< Operating Instructions SATAjet 3000 B RP (DIGITAL) >>
[3-4] Separate gauge without control device (accessory).
[3-5] Pressure regulation at the compressed air circuit (most
inaccurate method): rule of thumb: pressure at the pressure re-
ducer must be set 0.6 bar higher than the recommended spray gun
inlet pressure per every 10 m of air hose (inner width 9 mm).
7.2. Adjust material flow
rial flow control fully opened
With the material flow control fully opened, the wear of the fluid tip and
paint needle is reduced to a minimum. Please select the correct nozzle
size depending on the material to be applied and the required applica-
tion speed.
7.3. Adjust spray fan pattern
• Adjust flat fan (factory setting) [5-1].
• Adjust round fan [5-2].
7.4. Painting
For painting, the trigger has to be fully pulled [6-1]. Operate the spray
gun according to [6-2]. Maintain spray distance according to chapter 2.
8.
Cleaning of the paint spray gun
• Prior to cleaning, please disconnect the paint spray gun from the
compressed air circuit!
• Risk of injury due to unexpected leakage of compressed air or mate-
rial!
• Empty paint spray gun and gravity flow cup completely, dispose of
paint material appropriately!
• Disassemble and install components very carefully! Exclusively use
included special tools!
• Use neutral cleaning solution (pH value 6 to 8)!*
• Do not use acids, lyes, bases, pickling agents, unsuitable
regenerates or other aggressive cleaningsolutions!*
• Do not soak paint spray gun in cleaning solution!*
[4-1], [4-2], [4-3] und [4-4] - mate-
Note!
Warning! Attention!
EN
VII.7

Publicidad

Tabla de contenido
loading

Tabla de contenido