Cabinet Finish:
Cylinder:
Motor:
Electrical Boiler Horsepower:
Max. Air Flow:
Net Weight:
Electrical Requirements:
(Reversing Models)
75 LB.
CYLINDER
* 634 Models
M414670
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
75 Pound Steam Tumbler
Electrostatically applied thermosetting polyester.
37" x 36" (94 x 91.4 cm) perforated galvanized steel with four baffles;
75 pounds (34.1 kg) dry weight (cotton load)
High Pressure Steam — 3/4 H.P.
Low Pressure Steam — 3/4 H.P.
Both motors are lifetime lubricated, internal overload protected.
See below for reversing models.
High Pressure Steam — 4.60 BPH (154,100 BTU/hr.)
(72.1 kg/hr., 38,833 kCal/hr.)
Low Pressure Steam — 4.00 BHP (134,000 BTU/hr.)
(62.7 kg/hr., 33,768 kCal/hr.)
750 C.F.M. (354 liters/sec)
6 Coil Tumbler — 615 pounds (280 kg) (approximate)
208-240 Volt, 60 Hertz, 3 Phase, 4 Amp.
480 Volt, 60 Hertz, 3 Phase, 2 Amp
240 Volt, 50 Hertz, 1 Phase, 8 Amp
REVERSING MOTOR SIZES
GAS
1/3 H.P.
FAN
1 H.P.*
1/3 H.P.
ELECTRIC
HIGH
PRESSURE
1/3 H.P.
1/3 H.P.
1/3 H.P.
1/3 H.P.
STEAM
LOW
PRESSURE
1/2 H.P.
1/3 H.P.
19