ELECTRICAL REQUIREMENTS
For 120 Pound Tumblers
NOTE: Minimum wire sizes are obtained from Canadian Electrical Code and are intended for use as a guideline
only. Electrical connections should be made only by a qualified electrical contractor in accordance with all
applicable local and national requirements.
NOTE: DO NOT use aluminum wire.
Heat Source
Serial Plate Voltage
Gas & Steam
208-230V/60Hz/3ph
Gas & Steam
380-415V/50Hz/3ph
Gas & Steam
460-480V/60Hz/3ph
* Current Ratings vary slightly depending on model, see serial plate.
ELECTRICAL REQUIREMENTS
For 170 Pound Tumblers
NOTE: Minimum wire sizes are obtained from Canadian Electrical Code and are intended for use as a guideline
only. Electrical connections should be made only by a qualified electrical contractor in accordance with all
applicable local and national requirements.
NOTE: DO NOT use aluminum wire.
Heat Source
Serial Plate Voltage
Gas & Steam
208-230V/60Hz/3ph
Gas & Steam
380-415V/50Hz/3ph
Gas & Steam
460-480V/60Hz/3ph
* Current Ratings vary slightly depending on model, see serial plate.
48
Terminal Block
Connections Required
L1, L2, L3, and ground
L1, L2, L3, and ground
L1, L2, L3, and ground
Terminal Block
Connections Required
L1, L2, L3, and ground
L1, L2, L3, and ground
L1, L2, L3, and ground
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
Rated
Current
*
*
*
Table 13
Rated
Current
*
*
*
Table 14
Breaker
Breaker
Recommended
Rating
Poles
10 Amps
3
10 Amps
3
10 Amps
3
Breaker
Breaker
Recommended
Rating
Poles
30 Amps
3
20 Amps
3
15 Amps
3
Wire Size
14 AWG
14 AWG
14 AWG
Wire Size
10 AWG
12 AWG
14 AWG
M414670