ELECTRICAL REQUIREMENTS
For 30 Pound (31.5" Wide) Tumblers
NOTE: Minimum wire sizes are obtained from Canadian Electrical Code and are intended for use as a guideline
only. Electrical connections should be made only by a qualified electrical contractor in accordance with all
applicable local and national requirements.
NOTE: DO NOT use aluminum wire.
Heat Source
Serial Plate Voltage
Steam CSL
120V/60Hz/1ph
Gas & CSH
120V/60Hz/1ph
Gas & Steam
208 or 240V/60Hz/1ph
Gas & Steam
230-240V/50Hz/1ph
Gas & Steam
208 or 240V/60Hz/3ph
Gas & Steam
380 or 415V/50Hz/3ph
Gas & Steam
460-480V/60Hz/3ph
Electric
208V/60Hz/1ph
Electric
240V/60Hz/1ph
Electric
240V/50Hz/1ph
Electric
208V/60Hz/3ph
Electric
240V/60Hz/3ph
Electric
240V/50Hz/3ph
Electric
380V/50Hz/3ph
Electric
415V/60Hz/3ph
Electric
480V/60Hz/3ph
* Current Ratings vary slightly depending on model, see serial plate.
46
Terminal Block
Connections Required
L1, Neutral and ground
L1, Neutral and ground
L1, L2 and ground
L1, Neutral and ground
L1, L2, L3, and ground
L1, L2, L3, and ground
L1, L2, L3, and ground
L1, L2, and ground
L1, L2, and ground
L1, Neutral and ground
L1, L2, L3, and ground
L1, L2, L3, and ground
L1, L2, L3, and ground
L1, L2, L3, and ground
L1, L2, L3, and ground
L1, L2, L3, and ground
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
Rated
Current
*
*
*
*
*
*
*
104 Amps
92 Amps
90 Amps
62 Amps
55 Amps
53 Amps
33 Amps
30 Amps
28 Amps
Table 10
Breaker
Breaker
Recommended
Rating
Poles
20 Amps
1
15 Amps
1
15 Amps
2
15 Amps
1
15 Amps
3
15 Amps
3
15 Amps
3
125 Amps
2
100 Amps
2
100 Amps
1
70 Amps
3
60 Amps
3
60 Amps
3
40 Amps
3
35 Amps
3
35 Amps
3
Wire Size
12 AWG
14 AWG
14 AWG
14 AWG
14 AWG
14 AWG
14 AWG
0 AWG
2 AWG
2 AWG
4 AWG
4 AWG
4 AWG
8 AWG
8 AWG
8 AWG