Resetting The Pressure Switch Timing - Titan Impact 400 Instrucciones De Uso

Airless equipo de alta presión para pulverizar
Ocultar thumbs Ver también para Impact 400:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Impact 400
11.7

reSeTTINg The preSSure SWITch TImINg

The following procedure must only be performed
i
by a Titan Authorized Service Center.
The components of the pressure switch must be
i
properly reassembled and adjusted in order for
the pump to operate at the correct maximum
pressure.
Perform this procedure using pressure gauge P/N 0521229.
1. Make sure the knob bottom (1) is installed in the pressure
switch (2).
2. Viewing from the top, turn the knob bottom (1) counter-
clockwise as far as the teeth inside the pressure switch will
allow.
If the stop (3) on the pressure switch prevents the
i
knob bottom from continuing to turn, remove
the knob bottom, re-orient it on the teeth and
continue to turn it counterclockwise until it stops.
3. Re-orient the knob tab against the pressure switch tab
stop.
4. Replace the front cover and secure with the three screws.
5. Replace the pressure control knob into the knob bottom
but do not secure with the screw. Turn the knob fully
clockwise to maximum.
6. Connect the pressure gauge to the outlet fitting.
7. Connect a high-pressure hose and gun to the pressure
gauge.
8. Using water as a media, follow the steps in section 4.4. It
is not necessary to attach a spray tip to the gun. Leave the
pressure set to maximum.
9. The sprayer should now be pressurized at maximum
pressure. The pressure gauge should be reading between
193-207 bar.
10. If the pressure reading is below or above this reading, the
set screw down inside the pressure switch will have to be
adjusted. Adjust it per the guidelines below using a long
hex wrench.
a. If the pressure reading is below 193 bar, turn the set screw
b. If the pressure reading is above 207 bar, relieve pressure by
1
11. When the pressure gauge reads between 193-207 bar,
the pressure control knob is now set. Secure the pressure
control knob with the pressure control knob screw.
3
2
counterclockwise until the pressure gauge reads between
193-207 bar.
turning the valve handle to PRIME (k circulation). While
the sprayer is circulating, turn the set screw clockwise
slightly and then turn the valve handle to SPRAY (p spray).
Repeat this until the pressure reading decreases to a range
of 193-207 bar.
repairs at the unit
23

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

05320430532044

Tabla de contenido