Cleaning Airless Spray Gun; Remedy In Case Of Faults - WAGNER PS 3.20 Instrucciones De Uso

Unidade de pulverizacao de alta pressao airless
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Cleaning the unit (shutting down)
8.3

Cleaning Airless spray gun

1. Rinse Airless spray gun with an appropriate cleaning agent.
2. Clean tip thoroughly with appropriate cleaning agent so that
no coating material residue remains.
3. Thoroughly clean the outside of the Airless spray gun.
Intake filter in Airless spray gun (Fig. 7)
1. Unclip the top of the trigger guard (1) from the gun head.
2. Using the bottom of the trigger guard as a wrench, loosen and
remove the handle assembly (2) from the gun head.
3. Pull the old filter (3) out of the gun head. Clean or replace.
4. Slide the new filter, tapered end first, into the gun head.
5. Thread the handle assembly into the gun head. Tighten with
the trigger wrench.
6. Snap the trigger guard back onto the gun head.
9.

Remedy in case of faults

Type of malfunction
A. Unit does not start
B. Unit does not draw in material
C. Unit draws in material, but the
pressure does not build up
D.
Coating material exits at the top of
the fluid section
E.
Increased pulsation at the spray
gun
F.
Poor spray pattern
G. Unit loses power
H.
Pump over-pressurizes and will not
shut off.
GB
Possible cause
1.
No voltage applied.
2.
Pressure setting too low.
3.
ON/OFF switch defective.
1. Relief valve is set to SPRAY (p spray).
2.
Filter projects over the fluid level and
sucks air.
3.
Filter clogged.
4.
Suction hose/suction tube is loose, i.e.
the unit is sucking in outside air.
1.
Tip heavily worn.
2.
Tip too large.
3.
Pressure setting too low.
4.
Filter clogged.
5.
Coating material flows through the
return hose when the relief valve is in
the SPRAY (p spray) position.
6.
Packings sticky or worn.
7. Valve balls worn.
8. Valve seats worn.
1. Upper packing is worn.
2.
Piston is worn.
1.
Incorrect high-pressure hose type.
2.
Tip worn or too large.
3.
Pressure too high.
1.
Tip is too large for the coating
material which is to be sprayed.
2.
Pressure setting incorrect.
3. Volume too low.
4.
Coating material viscosity too high.
1.
Pressure setting too low.
1.
Pressure switch defective.
2.
Transducer defective.
1
Measures for eliminating the malfunction
1.
Check voltage supply.
2.
Turn up pressure control knob.
3.
Replace.
1.
Set relief valve to PRIME (k circulation).
2.
Refill the coating material.
3.
Clean or replace the filter.
4.
Clean connecting points. Replace O-rings if necessary.
Secure suction hose with retaining clip.
1.
Replace
2.
Replace tip.
3.
Turn pressure control knob clockwise to increase.
4.
Clean or replace the filter.
5.
Remove and clean or replace relief valve.
6.
Remove and clean or replace packings.
7.
Remove and replace valve balls.
8.
Remove and replace valve seats.
1.
Remove and replace packing.
2.
Remove and replace piston.
1.
Only use WAGNER original-high-pressure hoses in order
to ensure functionality, safety and durability.
2.
Replace tip.
3.
Turn pressure control knob to a lower number.
1.
Replace tip.
2.
Turn pressure control knob until a satisfactory spraying
pattern is achieved.
3.
Clean or replace all filters.
4. Thin out according to the manufacturer's instructions.
1.
Turn pressure control knob clockwise to increase.
1.
Take unit to a Wagner authorized service center.
2.
Take unit to a Wagner authorized service center.
10
Remedy in case of faults
3
2
ProSpray 3.20

Publicidad

Tabla de contenido
loading

Tabla de contenido