- If the roller shutter detects an obstacle when it is being
raised:
The roller shutter stops automatically.
7.1.6.
Anti-freeze protection
The anti-freeze protection function operates in the same way as the obstacle detection function:
-
If the Oximo 50 S Auto io detects any resistance, it does not move in order to protect the roller
shutter:
The roller shutter remains in the initial position.
7.2.
Operating with a Somfy io sun sensor
Refer to the corresponding guide.
8.
ADDITIONAL SETTINGS
8.1.
Favourite position (my)
8.1.1.
Modifying the favourite position (my)
1) Put the roller shutter in the desired favourite position
(my).
2) Press the «my» button until the roller shutter moves
(approx. 5 seconds.): the desired favourite position (my)
has been programmed.
8.1.2.
Deleting the favourite position
1) Press the «my» button:
The roller shutter starts to move and stops in the
favourite position (my).
2) Press the «my» button again until the roller shutter moves
briefly:
The favourite position (my) has been deleted.
8.2.
Adding/Deleting Somfy io control points and io sensors
Refer to the corresponding guide.
8.3. Modifying the direction of rotation
The direction of rotation may be modified at any time using
a programmed Somfy local io control point.:
1) Place the roller shutter in the middle position.
2) Simultaneously press the Up and Down button until the
roller shutter moves (approx. 5 seconds.).
3) Press the «my» button until the roller shutter moves
again: the direction of rotation has been reversed.
4) Press the Up button to check the new direction of
rotation.
For modifying the direction of rotation using other io control
point, refer to the corresponding guide.
9.
TIPS AND RECOMMENDATIONS
9.1.
Questions on the Oximo 50 S Auto io?
Observations
The roller shutter is not
operational.
Copyright © 2010 Somfy SAS. All rights reserved.
Possible causes
The wiring is incorrect.
The motor is in heat protection mode.
An incorrect cable has been used.
Oximo 50 S Auto io
1
2
or
my
1
2
my
1
2
3
4
Solutions
Check the wiring and modify it if
necessary.
Wait until the motor cools down.
Check the cable and ensure it has
3 leads
my