"ACTIVE ALARM" "AL 2 - FUME PROBE": the probe is damaged or disconnected.
• Reset the error with P4 key. The stove carries out the phase "FINAL CLEANING" and the is in "OFF".
• Check the type of glitch as ALARMS page 89.
• Clean the burning pot and start the stove up again with P4 key.
11.4
"HOT FUME" ALARM
EN
If the fume probe registers a temperature at the exhaust higher then 180°C, the display shows "HOT FUME".
Then the combustible (pellet) drop will be decreased at phase 1.
This function has the aim to bring the values within preset values. If for any reason the temperature would
not decreas but increase, at 215°C the display shows "ACTIVE ALARM" "AL 3 - HOT FUME" and the stove
start the switching off phase up.
• Reset the error with P4 key. The stove carries out the phase "FINAL CLEANING" and the is in "OFF".
• Check the type of glitch as ALARMS page 89.
• Clean the burning pot and start the stove up again with P4 key.
11.5
"FAN FAILURE" ALARM
"ACTIVE ALARM" "AL 4 - FAN FAILURE": the fume fan is out of order.
• Reset the error with P4 key. The stove carries out the phase "FINAL CLEANING" and the is in "OFF".
• Check the type of glitch as ALARMS page 89.
• Clean the burning pot and start the stove up again with P4 key.
11.6
"FAILED IGNITION" ALARM
"ACTIVE ALARM" "AL 5 - FAILED IGNITION": the temperatureis not sufficient for ignition.
• Reset the error with P4 key. The stove carries out the phase "FINAL CLEANING" and the is in "OFF".
• Check the type of glitch as ALARMS page 89.
• Clean the burning pot and start the stove up again with P4 key.
11.7
"NO PELLET" ALARM
If the fume probe registers a temperature at the exhaust lower than the minimum threshold and the display
shows "ACTIVE ALARM" "AL 6 - NO PELLET".
• Reset the error with P4 key. The stove carries out the phase "FINAL CLEANING" and the is in "OFF".
• Full the hopper.
• Clean the burning pot and start the stove up again with P4 key.
11.8
"THERMAL SAFETY" ALARM
In the hopper is installed a automatic thermostat which activates if the temperature excursion exceeds
the allowed limits, so avoiding the possibility that the pellet inside the hopper could burn because of
overheating.
"ACTIVE ALARM" "AL 7 - THERMAL SAFETY": the thermostat stops the power supply to the auger.
• Reset the error with P4 key. The stove carries out the phase "FINAL CLEANING" and then is in "OFF".
• Check the type of glitch as ALARMS page 89.
• Clean the burning pot and start the stove up again with P4 key.
11.9
"FAILURE DEPRESS" ALARM
To the boiler is connected a pressostat which control the depression and in some stove models on the fire
door id installed a microswitch which registers the opening.
"ACTIVE ALARM" "AL 8 - FAILURE DEPRESS": the pressostat and/or fire door which is not correctly closed
stops the power supply to the auger.
• Reset the error with P4 key. The stove carries out the phase "FINAL CLEANING" and then is in "OFF".
• Check the type of glitch as ALARMS page 89.
• Clean the burning pot and start the stove up again with P4 key.
82
CLOE - SQUARE