ALARM
CAUSE
Empty hopper
EN
The burning pot has not
been cleaned
The ignition threshold
has not been reached
Faulty ignition plug
AL 5 - FAILED
IGNITION
Too sever external
temperature
Humid pellet
Blocked thermal probe
Faulty mother board
AL 6 - NO
Empty hopper
PELLET
Boiler overheating
The ambient exchanger
fan does not work
AL 7 -
THERMAL
Temporary power cut
SAFETY
Faulty automatic
thermostat
Faulty mother board
90
SOLUTION
Fill the hopper.
Clean the burning pot.
Clean the burning pot and switch the stove on
again.
Replace the ignitor resistance.
Start the stove up again.
The pellets must be stored in a dry place. Please
check it.
Replace the thermal probe.
Replace the mother board.
Full the hopper.
Let the stove cooling. (If the problem persits please
call an Authorized Technician).
Replace the ambient fan.
The lack of tension during the running implies the
overheating of the boiler and the intervention of the
automatic thermostat. Let the stove cooling and start
the stove up again.
Replace the automatic thermostat.
Replace the mother board.
INTERVENTION
CLOE - SQUARE