5.3 Advanced programming
Here are some added programming procedures relating to remotes memory management and advanced configuration of the
control inputs.
1
Deletion of memorized transmitters
1.1 Deletion of all transmitters
1. Scroll down the parameters until you visualize P004;
2. Confirm by pressing on the
3. When "
" is flashing, press the
seconds;
4. Release the
key as soon as "
5. All memorized transmitters have been deleted (display
shows again P004).
1.2 How to search and delete a transmitter
1. Scroll down the parameters until you visualize P006;
2. Confirm by pressing on the
3. By pressing on
and
you want to delete (eg.
4. When "
" flashes, confirm the deletion by pressing
the
key for a few seconds;
5. Release the
key when appears "
6. The selected transmitter is deleted (display shows again
P006).
2
Inputs configuration
Where the installation requires different commands and / or additional
to the standard ones described by plans on page 22, you can configure
each input for the operation desired (eg START, PHOTOS, STOP , etc ...).
1. Scroll down the parameters with the
sponding to the desired one:
● P010=for INPUT 1;
● P011=for INPUT 2;
● P012=for INPUT 3;
● P013=for INPUT 4;
● P014=for INPUT 5;
2. Confirm by pressing on the
(eg. P012);
3. Scroll down with the
and
to the desired operation (refer to table "Input Configuration para-
meters" on page 20);
4. Confirm by pressing on the
5. Execute the new connection to the input just reconfigured.
6 UNLOCKING AND MANUAL OPERATION
In the event of malfunctions or simple power failure, release the motor (Pic. 9) and perform the operation manually.
The knowledge of the unlocking device is very important because, in times of emergency, lack of speed in operating this device can
cause danger.
WARNING The efficancy and safety of manual operation of the automation is guaranteed by DEA System only if the installation
has been installed correctly and with original accessories.
7 START-UP
The start-up phase is very important to ensure maximum security and compliance to regulations, including all the requirements of
EN 12445 standard which establishes the test methods for testing the automation for gates.
DEA System reminds that all installation, maintenance, cleaning or repair operations on any part of the system must be performed
exclusively by qualified personnel who must be responsible of all texts requie by the eventual risk;
key;
key for a few
" stops flashing;
key;
, keys, select the transmitter
);
";
and
to see that corre-
key to get access to the parameter
, keys to set the value corresponding
key (display shows again P012).
EN
17