Ecco 3 in 1
The following table helps in localising and remedying minor faults:
Fault
The indicator does not
light up after inserting the
mains plug
The fuse in the distributor
box triggers.
Kettle (9) cannot be
switched on. Power indica-
tor does not light up.
Kettle (9) does not auto-
matically switch off.
Kettle (9) switches off
prematurely.
Filter compartment (21)
cannot be swivelled out
properly.
The coffee runs too slowly
into the glass jug (16).
NOTE
►
If you cannot resolve the problem with the steps described above, please contact
customer service.
30
Troubleshooting
Possible cause
Fuse in electrical distribution
board switched off.
The indicator lamp is defective. Contact customer service.
Too many appliances connect-
ed to the same power circuit.
No fault detected.
Kettle (9) is not standing on the
socket properly (10).
On/off switch (6) is blocked.
Lid is not closed properly.
Boil-dry safety protection was
triggered
Permanent filter (18) is not
properly seated in the filter
compartment (21).
Drip-stop (19) is blocked.
Coffee machine scaled.
remedy
Switch on fuse.
Reduce the number of
appliances on the power
circuit.
Contact customer service.
Put the kettle (9) onto
the socket (10) so that it
snaps in properly.
Remove the blockage.
Close lid.
Reset the dry-boil protec-
tion as described in the
section Resetting the
boil-dry protection
(page 25).
Pay attention to proper
seating.
Clean the drip-stop (19).
Descale coffee machine.
See section Descaling
(page 27).
BEEM - Elements of Lifestyle
EN