EdilKamin TINY Instalación Uso Y Mantenimiento página 53

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 86
TROUBLESHOOTING TIPS FOR TINY
In the event of problems the stove stops automatically and runs the shutdown process and the display shows text
regarding the motivation of the shutdown (see the various alarms below).
Never pull the plug during shutdown on account of malfunction.
Should it block, to restart the stove you will need to allow the turn-off procedure to take place (600 seconds with
audible signal), and then press the button
Do not turn the stove on again before checking the cause of the malfunction and CLEANING/ EMPTYING the crucible.
INDICATION OF POSSIBLE CAUSES OF MALFUNCTION AND INDICATIONS AND REMEDIES:
1) Verific./air flow: (intervenes if the flow sensor detects insufficient combustion air flow).
Turns off for lack of depression
Air flow may be insufficient because the door is open, the door does not close properly (e.g. bad seal), there is an air
intake or smoke extraction problem, or the combustion chamber is clogged.
Check:
- door closure;
- combustion air intake duct (clean, paying attention to the flow sensor components);
- clean the flow sensor with dry air (like that used for PC keyboards);
- stove location: it must not be installed against a wall;
- combustion chamber position and cleanliness (clean regularly according to the type of pellet);
- smoke duct (clean);
- installation (if it does not comply with regulations or the smoke outlet has more than 2-3 bends);
If you suspect the sensor is malfunctioning, carry out cold tests. If the conditions are changed (for example by opening
the door) and the value does not change, there is a sensor problem.
The no depression alarm may also occur during ignition, since the flow sensor starts monitoring 90 seconds after the
ignition cycle begins.
2) Verific./extract.: (intervenes if the smoke extractor revolutions sensor detects an anomaly)
Turns off due to smoke expulsion motor
- Check smoke extractor function (devolution sensor connection) and board.
- Check smoke channel for dirt
- Verify the electrical system and earthing system.
- Check eletronic circuit board
3) Stop/Flame: (intervenes if the thermo coupling reports a smoke temperature below a value set, thereby interpreting it as a
lack of flame). Turns off due to drop in smoke temperature
Flame may fail for any of the following reasons:
- lack of pellets
- too many pellets have suffocated the flame
- the maximum thermostat has intervened (rare, this only intervenes in the event of excessive smoke temperature)
4) Block_FI/NO Start: (intervenes if a flame fails to appear within a maximum of 15 minutes, or if ignition temperatu-
re is not reached). Turns off due to incorrect smoke temperature during ignition
Distinguish either of the following cases:
The flame has NOT appeared
Check:
- correct positioning and cleanliness of combustion chamber
- resistance function
- room temperature (if less than 3°C) and moisture content.
- Try to ignite with Diavolina®
.
The flame has appeared but after the wording Ignition,
the wording Block_FI/NO Start has appeared.
Check :
- thermo coupling function
- ignition temperature set in the parameters
53

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Kelly

Tabla de contenido