Inverter serial number.
FW APP
Firmware application
FW BOOT
Firmware start-up.
FW LCD APP
Firmware application of the display.
FW LCD BOOT
Firmware start-up of the display.

10.21. Reset to default settings

If you want to delete all configurations made and accumulated values, thus returning the unit to the default
settings, you need to perform a reset.
To perform a factory reset access Main menu > Advanced settings > Factory reset. Press

10.22. Perform a ventilation test

Occasionally you need to test the proper performance of the unit's fans. These units have the option of performing
a ventilation test.
To perform the ventilation test access Main menu > Settings > Ventilation Test. Press
unit's fans start to turn. Wait until the display shows that the test has finished. If one or several of the fans do not
turn, a ventilation fault is displayed. If all ventilators turn, the test's result is positive.
INFO
The ventilation test only checks the turning of the fans. A positive ventilation test alone does not indicate that
the system's ventilation status is correct. To assure proper performance of the ventilation system, also check
that there are no elements obstructing air passage and that the fans are properly installed.

10.23. Performing an autotest

Autotest allows for the grid voltage and frequency limits to be tested automatically, checking that the unit
disconnects correctly within the time set by standard. This menu is only available for some standards, such as CEI
0-21 SPI INTERNAL.
During the autotest it checks the required variables for the selected standard.
There are three different states:
Not performed
No autotest running and none has been performed during the time in which the inverter has
been switched on.
Reconnection
State awaiting reconnection for the next measurement after an Fmax, Fmin, Vmax or Vmin
check.
Completed
A full autotest has been carried out during the time in which the inverter has been switched on.
Press
on Start Autotest to start autotest. Access Result to consult the results of the different tests,
observing whether the result is correct or incorrect. An autotest can be stopped when running by pressing
Stop Autotest.
The results screens for an autotest are then displayed if the test has been completed and a second case in which
the test has not been completed:
134
11/20/2016
11/20/2016
10:17 AM
10:17 AM
to start the reset.
to start the test. The
ABO2011IQM01_A - Installation and Operation Manual