Danfoss VLT AQUA Guía De Programación página 88

Ocultar thumbs Ver también para VLT AQUA:
Tabla de contenido

Publicidad

Descripción del parámetro
8-37 Retardo máximo intercarac.
Range:
Size related
*
35.00 ms]
3
3
3.9.4 8-4* Selección de telegrama
8-40 Selección de telegrama
Option:
[1]
Telegram.estándar1
[101] PPO1
[102] PPO 2
[103] PPO 3
[104] PPO 4
[105] PPO 5
[106] PPO 6
[107] PPO 7
[108] PPO 8
[200] Telegrama person. 1
8-42 PCD Write Configuration
Option:
[0]
None
[302]
Minimum Reference
[303]
Maximum Reference
[341]
Ramp 1 Ramp Up Time
[342]
Ramp 1 Ramp Down Time
[351]
Ramp 2 Ramp Up Time
[352]
Ramp 2 Ramp Down Time
[380]
Jog Ramp Time
[381]
Quick Stop Ramp Time
[411]
Motor Speed Low Limit [RPM]
[413]
Motor Speed High Limit [RPM]
[416]
Torque Limit Motor Mode
[417]
Torque Limit Generator Mode
[590]
Digital & Relay Bus Control
88
Función:
[ 0.00 -
Especifique el intervalo máximo de
tiempo admisible entre la recepción
de dos bytes. Este parámetro activa
el tiempo límite si se interrumpe la
transmisión.
Función:
Permite el uso de telegramas
configurables libremente o de
telegramas estándar para el puerto
FC.
Función:
Selec. par. para
asignación a
telegramas de PCD.
El número de los
PCD disponibles
depende del tipo de
telegrama. Los
valores de los PCD se
escribirán en los
parámetros
seleccionados como
valores de datos.
MG20O505 - VLT
Guía de programación del convertidor de frecuencia VLT
8-42 PCD Write Configuration
Option:
[593]
[595]
[597]
[653]
[663]
[890]
[891]
[894]
[895]
[896]
[1680] Fieldbus CTW 1
[1682] Fieldbus REF 1
[1685] FC Port CTW 1
[1686] FC Port REF 1
[2643] Terminal X42/7 Bus Control
[2653] Terminal X42/9 Bus Control
[2663] Terminal X42/11 Bus Control
8-43 PCD Read Configuration
Option:
[0]
[894]
[895]
[896]
[1500] Operating Hours
[1501] Running Hours
[1502] kWh Counter
[1600] Control Word
[1601] Reference [Unit]
[1602] Reference [%]
[1603] Status Word
[1605] Main Actual Value [%]
[1609] Custom Readout
[1610] Power [kW]
[1611] Power [hp]
[1612] Motor Voltage
[1613] Frequency
[1614] Motor Current
[1615] Frequency [%]
[1616] Torque [Nm]
[1617] Speed [RPM]
®
es una marca registrada de Danfoss
®
AQUA
Pulse Out #27 Bus Control
Pulse Out #29 Bus Control
Pulse Out #X30/6 Bus Control
Terminal 42 Output Bus Control
Terminal X30/8 Output Bus Control
Bus Jog 1 Speed
Bus Jog 2 Speed
Bus Feedback 1
Bus Feedback 2
Bus Feedback 3
None
Bus Feedback 1
Bus Feedback 2
Bus Feedback 3
Función:
Función:
Selec. par. para
asignación a los
PCD de los
telegramas. El
número de PCD
disponibles
depende del tipo
de telegrama. Los
PCD contienen los
valores reales de
los parámetros
seleccionados.

Publicidad

Tabla de contenido
loading