16. Technical data

16.1 Enclosure

The individual CUE cabinet sizes are characterised by their
enclosures. The table shows the relationship of enclosure class
and enclosure type.
Example:
Read from the nameplate:
Supply voltage
= 3 x 380-500 V.
Typical shaft power = 110 kW.
Enclosure class
= IP21.
The table shows that the CUE enclosure is D1.
Enclosure class and type
Typical shaft
power P2
3 x 380-500 V
IP21
[kW]
[HP]
NEMA1
110
150
D1
132
200
160
250
200
300
D2
250
350

16.2 Main dimensions and weight

Fig. 47 Enclosures D1 and D2
Height [in]
Enclosure
A
D1
47.6
D2
62.6
Shipping dimensions
D1
25.6
D2
25.6
1)
The dimensions are maximum height, width and depth. Dimensions are without options.
3 x 525-690 V
IP54
IP21
IP54
NEMA12
NEMA1
NEMA12
D1
D1
D1
D2
D2
D2
1)
1)
Width [in]
a
B
b
45.4
16.5
12.0
60.4
16.5
12.0
68.1
68.1
1)
Screw holes [in]
Depth [in]
∅d
C
c
15.0
0.79
0.43
15.0
0.79
0.43
22.4
22.4
Weight [lb]
∅e
f
0.43
0.98
229
0.43
0.98
333
39