SATA filter 100 prep Instrucciones De Servicio página 252

Ocultar thumbs Ver también para filter 100 prep:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 64
<< Operating instructions SATA filter 100/101/103 prep >>
• Remove condensate cyclone separator [4-1] from the filter stage
[A], remove and check insert as well as sintered filter [4-2]. Clean or
replace if necessary
• Remove [4-3] and replace fine or activated charcoal cartridge on filter
stages [B] and [C]
• Installation has to be carried out in reverse order. Please make sure
that the filter cartridges are installed in the correct order. Coloured
markers (yellow = sintered filter [A], blue = fine filter [B], black =
activated charcoal filter [C] allow clear identification [4-4]. Marking
rings are located on the threaded rods of the filter stages [B] and [C],
adhesive stickers [1-7], [1-11], [1-13] on the filter housings.
• During installation, please ensure proper seat and undamaged O-rings!
Note!
Please observe local regulations for the disposal of filter cartridges!
11. Trouble-shooting
Malfunction
Pressure cannot be
properly adjusted
Traces of compressor
oil in the compressed
air
No or insufficient con-
densate drainage (a
minimum condensate
level is required as it
serves to lift the floater
and, thus, to open the
drain valve)
Cause
Insufficient inlet pres-
sure
Pressure regulation
valve at air outlet mod-
ule is defective
Too much oil in the
compressed air
Saturated filter
Floater stuck on the
drain valve
Damaged drain valve
Corrective action
Increase inlet pressure
Exchange air outlet
module [D], Art. No.
148239
Control compressor,
refrigerated dryer
Drain condensate
(open manually)
Filter maintenance
required, chapter 10
Disassemble drain
valve by removing the
safety disc, then clean
or exchange drain
valve
Exchange drain valve
Art. No. 15511
US
XXVI.7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Filter 101 prepFilter 103 prep

Tabla de contenido