Operating Instructions SATAjet 5000 B RP/HVLP PHASER
EN
6.2. Specific Safety Instructions for Spray Guns
• Local safety, accident prevention, work and environment protection
regulations are mandatory!
• Never direct a spray gun at human beings or animals!
• Use, cleaning and maintenance by skilled personnel only!
• People whose ability to react is impaired by drugs, alcohol, medication
or for other reasons are not allowed to use a spray gun!
• Never start using the spray gun when damaged or when parts are
missing! In particular, only use when the locking screw [1-14] has
been securely fitted! Tighten the locking screw with max. 1 Nm using
the original SATA combi-tool.
• Before use, the spray gun should always be checked and repaired, if
necessary!
• Put spray gun immediately out of operation when damaged, discon-
nect it from the compressed air circuit!
• Never manipulate or technically modify the spray gun!
• Use original SATA spare parts and accessories only!
• Exclusively use spray gun washing machines recommended by SATA!
Please observe the operating instructions!
• Never spray materials containing acid, lye or benzine!
• Alyways keep the spray gun away from ignition sources, such as open
fire, burning cigarettes or non-explosion-proof electronic devices!
• When working with the spray gun, always limit solvents, paints or
other coating media to the quantities which are required for the paint
job! Excessive material must be returned to the designated storage
areas afterwards!
106
Warning! Attention!