Operating Instructions SATAjet 5000 B RP/HVLP PHASER
7.1. Adjust spray gun inlet pressure
• Pull the trigger fully and adjust the spray gun inlet pressure (see
chapter 2) following instructions of one of the followig sections ([3-1],
[3-2], [3-3] to [3-4]), then release the trigger.
• For [3-3] and [3-4], the air micrometer [1-13] must be fully open/
stand vertically.
• Increase the pressure in the compressed air circuit if the necessary
gun input pressure is not reached; if the pressure is too high, this
causes high trigger forces.
[3-1] SATA adam 2 (accessory / accurate method).
[3-2] Separate gauge with control device (accessory).
[3-3] Separate gauge without control device (accessory).
[3-4] Pressure regulation at the compressed air circuit (most inaccu-
rate method).
7.2. Adjust material flow
rial flow control fully opened
With the material flow control fully opened, the wear of the fluid tip and
paint needle is reduced to a minimum. Please select the correct nozzle
size depending on the material to be applied and the required applica-
tion speed.
7.3. Adjust spray fan pattern
• Adjust flat fan (factory setting) [5-1].
• Adjust round fan [5-2].
7.4. Painting
Fully pull trigger for painting [6-1]. Operate spray gun according to [6-2].
Maintain spray distance as described in chapter 2.
Notice!
[4-1], [4-2], [4-3] und [4-4] - mate-
Notice!
EN