Enable/Disable Expansion Port; Enable/Disable Rain Sensor Terminals; Firmware Version; Automatic Circuit Breaker - Irritrol KD2 Guia Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Enable/Disable Expansion Port

Your KD2 controller is compatible with many of Irritrol's
controller enhancement products like the Climate Logic
Weather Sensing System (CL -100 -WIRELESS) and the
Climate Logic
Hand -Held Remote (R -100 -KIT) by way
TM
of the built -in expansion port. The provided expansion
port for Climate Logic
devices must be switched ON to
TM
enable operation. See item 7 on page 2 for the location of
the expansion port. The expansion port is switched ON by
default when assembled at the factory.
1. Turn control dial to
2. Press the
button as needed to select the expansion
port switch option designated by XP N.
button to select Y (yes, expansion
3. Press the
or
port on), or N (expansion port off).
4. Return the control dial to
finished.

Enable/Disable Rain Sensor Terminals

To utilize the sensor terminals, RS must be set to Y.
Selecting N will bypass the sensor terminals and the
controller will function normally regardless of the input at
the sensor terminals.
1. Turn control dial to
button as needed to select RS N.
2. Press the
button to select Y (yes) to enable or
3. Press the
or
N (no) to disable sensor inputs.
4. Return the control dial to
finished.
Special Functions position.
HOME position when
Special Functions position.
HOME position when

Firmware Version

To check your KD2's firmware version, place the control
Special Functions position and press the
dial to
TM
button as needed until the firmware version is displayed
(V001 or later).

Automatic Circuit Breaker

The KD2 controller features an electronic circuit breaker
which automatically detects an overload condition on a
station terminal during operation and turns off the station
before controller damage can occur. The KD2 advances to
the next programmed station in sequence to continue the
watering cycle.
After the program watering cycle has finished, FUSE and
the number of the skipped station(s) will be displayed in
alternating sequence with the current time of day. If all of
the station numbers and FUSE are displayed, the master
valve is malfunctioning. Pressing any button will remove
the warning display.
Important: The most common cause of an overload
condition is a short circuit in the valve wiring or a
malfunctioning valve solenoid. The cause of the overload
condition should be corrected before continuing to operate
the controller.