5. Check the distance between contacts with a thickness gauge.
Vary the distance moving the lateral electrode. Correct distance
between contact is: 0.70- 0.80mm.
6. Check that the spark plug o-ring is in good condition. Screw it in
with the spark plug key to protect the tapping.
Normal maintenance time
Element
Check oil lever
Engine oil
Change oil
Check
Filter
Clean
Spark plug
Fuel supply
Rotor
Pump hosing cover
Water inlet
(1) If the pump is used in a dirty environment the inspection and maintenance operations should be carried out more frequently.
(2) If you as the user do not posses the necessary tools or knowledge for these operations, please contact an authorised distributor to carry
out the inspection and maintenance test detailed below. If you consider yourself capable of such tests always consult the maintenance
manual.
NOTE
Where it is necessary to install a new spark ignition turn it further
half a rotation once the spark plug reaches the position of the o-ring
in such a way that it provides pressure. If the spark plugs are worn,
the additional turn should be a quarter or half rotation.
ATTENTION
Ensure the spark ignition is adequately tightened. Incorrect tighte-
ning could cause the overheating of the motor. Never use spark plugs
with an incorrect thermal range.
Maintenance periods table
Every
Every month or
Every 3 months
time
20 hours
or 50 hours
X
X
X
Change every 2 years
32
Every 6 months
or 100 hours
X
X
X (1)
EN
Every year or
300 hours
X (2)
X (2)
X (2)
X (2)