30" DUAL FUEL SLIDE-IN RANGE INSTALLATION INSTRUCTIONS
Open the shutoff valve in the gas supply line. Wait a few
minutes for gas to move through the gas line.
The gas supply between the shutoff valve and the
regulator may be connected by rigid piping or by A.G.A./
C.G.A.-approved flexible metallic union-connected
piping where local codes permit use.
The gas supply piping can be through the side wall of
the right cabinet. The right side cabinet is an ideal
location for the main shutoff valve.
Do not make the connection too tight.
The regulator is die cast. Overtightening may crack the
regulator resulting in a gas leak and possible fire or
explosion.
Assemble the flexible connector from the gas supply pipe
to the pressure regulator in this order: 1- manual shutoff
valve, 2- flare union adapter, 3- flexible connector,
4- flare union adapter, 5- pressure regulator.
The gas supply line to the shutoff valve should be 1/2" or
3/4" solid pipe.
The user must know the location of the main shutoff
valve and have easy access to it.
When using flexible gas conduit on the range, allow
sufficient slack to pull the range outside the cutout for
cleaning or servicing.
PRESSURE
REGULATOR
LOCATION
(Models with an Electric Oven and a Gas Cooktop)
REAR
WIRE
ACCESS
COVER
Figure 7
NOTE: Do not allow the flexible conduit to get pinched
between the wall and the range. To visually check,
remove the range drawer.
Use pipe-joint compound made for use with Natural and
LP/Propane gas to seal all gas connections. If flexible
connectors are used, be certain connectors are not
kinked.
Leak testing of the appliance shall be conducted
according to the manufacturer's instructions.
Check for leaks. After connecting the range to the gas
supply, check the system for leaks with a manometer. If
a manometer is not available, turn on the gas supply and
use a liquid leak detector at all joints and connections to
check for leaks.
Do not use a flame to check for leaks
from gas connections. Checking for leaks with a flame
may result in a fire or explosion.
All openings in the wall or floor where the range is to be
installed must be sealed.
Tighten all connections if necessary to prevent gas
leakage in the cooktop or supply line.
Check alignment of valves after connecting the
cooktop to the gas supply to be sure the manifold pipe
has not been moved.
6