Sears Kenmore Elite 66495223710 Instrucciones De Instalación página 10

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3. Feed the power supply cord through the strain relief on the
cord/conduit plate on bottom of range. Allow enough slack
to easily attach the wiring to the terminal block.
A
C
A. Terminal block
B. Ground-link screw
C. UL Listed strain relief
D. Power supply cord wires
4. Use a Phillips screwdriver to connect the green ground wire
from the power supply cord to the range with the ground-
link screw and ground-link section. The ground wire must be
attached over the ground-link section.
5. Use
3
/
" (1.0 cm) nut driver to connect the neutral (white)
8
wire to the center terminal block post with 1 of the 10-32
hex nuts.
A
B
C
A. 10-32 hex nut
B. Ground-link screw
C. Line 2 (red) wire
6. Connect line 2 (red) and line 1 (black) wires to the outer
terminal block posts with 10-32 hex nuts.
7. Firmly tighten hex nuts.
NOTE: For power supply cord replacement, use only a
power cord rated at 250 volts minimum, 40 or 50 amps,
that is marked for use with nominal 1
connection opening, with ring terminals and marked for use
with ranges.
8. Tighten strain relief screws.
IMPORTANT: Verify the tightness of the hex nuts.
9. Replace lower access cover.
10
B
D
F
E
D
D. Green ground wire
E. Neutral (white) wire
F. Line 1 (black) wire
/
" (3.5 cm) diameter
3
8
Install Using Direct Wire
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper or 6 gauge aluminum wire.
Electrically ground range.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Direct Wire Strain Relief
1. Disconnect power.
2. Remove the lower access cover screws located on the back
of the range. Pull the bottom of the cover toward you and
out to remove cover from range.
A. Mounting tabs (3)
B. Lower access cover
C. Screws (2)
A
B
C

Publicidad

Tabla de contenido
loading

Tabla de contenido