2. Attach terminal lugs to line 2 (red), bare (green) ground,
and line 1 (black) wires. Loosen (do not remove) the
setscrew on the front of the terminal lug and insert exposed
wire end through bottom of terminal lugs. Securely tighten
setscrew to torque as shown in the following Bare Wire
Torque Specifications chart.
C
A. Terminal lug
B. Setscrew
C. Line 2 (red) wire
D. Bare (green) ground wire
E. Line 1 (black) wire
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 lbs-in.
(2.3 N-m)
Wire Awg
8 gauge copper
6 gauge aluminum
3. Use
/
" (1.0 cm) nut driver to connect the bare (green)
3
8
ground wire to the center terminal block post with 1 of
the 10-32 hex nuts.
A
B
A. 10-32 hex nut
B. Line 2 (red) wire
C. Ground-link screw
4. Connect line 2 (red) and line 1 (black) wires to the outer
terminal block posts with 10-32 hex nuts.
5. Firmly tighten hex nuts.
IMPORTANT: Verify the tightness of the hex nuts.
6. Replace lower access cover.
12
A
B
D
E
Torque
25 lbs-in. (2.8 N-m)
35 lbs-in. (4.0 N-m)
F
E
D
C
D. Bare (green) ground wire
E. Line 1 (black) wire
F. Terminal lug
4-Wire Connection: Direct Wire
Use this method for:
New branch-circuit installations (1996 NEC)
■
Mobile homes
■
Recreational vehicles
■
In an area where local codes prohibit grounding through
■
the neutral
1. Cut out and remove part of metal ground strap, as shown.
A. Metal ground strap
B. Discard
C. Ground-link screw
2. Use a Phillips screwdriver to remove the ground-link screw
from the back of the range. Save the ground-link screw
and the end of the ground link under the screw.
3. Pull the wires through the strain relief on bottom of
range. Allow enough slack to easily attach wiring to
the terminal block.
A
D
E
F
A. Terminal block
B. Ground-link screw
C. Cord/conduit plate
D. Bare (green) ground wire
A
B
C
B
C
G
E. Line 2 (red) wire
F. Neutral (white) wire
G. Line 1 (black) wire