3. Depending on your model, remove plastic tag holding three
10-32 hex nuts from the middle post of the terminal block.
Remove the top 10-32 hex nut from each of the 3 terminal
blocks and set aside.
4. Assemble a UL Listed conduit connector in the opening.
A. Removable retaining nut
B. Conduit
5. Tighten strain relief screw against the flexible conduit.
Direct Wire Installation: Copper or Aluminum Wire
This range may be connected directly to the fuse disconnect or
circuit breaker box. Depending on your electrical supply, make
the required 3-wire or 4-wire connection.
OR
A
B
1. Strip outer covering back 3" (7.6 cm) to expose wires. Strip
the insulation back
3
/
" (1.0 cm) from the end of each wire.
8
2. Allow enough slack in the wire to easily attach the wiring
terminal block.
3. Complete installation following instructions for your type
of electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
Electrical Connection Options
If your home has:
And you will be
connecting to:
3-wire direct
A circuit breaker
box or fused
³⁄₈"
(1.0 cm)
disconnect
3"
(7.6 cm)
4-wire direct
A circuit breaker
box or fused
³⁄₈"
(1.0 cm)
disconnect
5"
(12.7 cm)
3-Wire Connection: Direct Wire
Use this method only if local codes permit connecting ground
conductor to neutral supply wire.
1. Pull the wires through the conduit on cord/conduit plate on
bottom of range. Allow enough slack to easily attach the
wiring to the terminal block.
A
D
E
A. Terminal block
B. Ground-link screw
C. Cord/conduit plate
³⁄₈"
(1.0 cm)
3"
(7.6 cm)
Go to section:
3-Wire Connection:
Direct Wire
4-Wire Connection:
Direct Wire
B
C
F
D. Line 2 (red) wire
E. Bare (green) ground wire
F. Line 1 (black) wire
11