Configuration Options - Balluff BTL7-A/C/E/G50 Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 107
BTL7-A/C/E/G50_-M_ _ _ _ -T_2/3-NEX-S32/KA_ _
Micropulse Transducer - Rod Style
6
Configuration with the Micropulse Configuration Tool (continued)
6.3

Configuration options

Prerequisites
USB communication box connected to the transducer
and PC.
Software correctly installed.
Transducer connected to the power supply.
Magnet on transducer.
Output functions
Position: Position in the measuring range.
Velocity: velocity of the magnet. The sign indicates the
direction of movement. Movement from the null point
to the end point is output with a positive sign.
Movement from the end point to the null point is output
with a negative sign. Max. detectable velocity range of
−10 to +10 m/s.
Velocity (no sign): velocity of the magnet. The
direction of movement cannot be read. Max.
detectable velocity range of 0 to 10 m/s.
Freely configurable curve
Null and end point can be read (teach-in) or specified
with the mouse.
For position, the distance between the null point and
end point must be at least 4 mm (0.15 inch) and
100 mm/s (4 inch/s) for velocity.
The characteristic curve can be inverted.
The limits can be adjusted to the measuring range.
The error value can be set in accordance with the
limits.
Output gradient
Linear
transducer
Rising
BTL7-A...
BTL7-G...
BTL7-C...
BTL7-E...
Falling
BTL7-A...
BTL7-G...
BTL7-C...
BTL7-E...
Tab. 6-1:
Factory settings value table
www.balluff.com
Uncontrolled system movement
When starting up, if the position measuring system is
part of a closed loop system whose parameters have not
yet been set, the system may perform uncontrolled
movements. This could result in personal injury and
equipment damage.
► The system must be taken out of operation before
configuration.
► Transducers may only be connected to the
communication box for configuration.
► The communication box must be removed after
configuration.
Null point
Unit
Min. value
Null value
V
−0.5
V
−10.5
−10
mA
0
mA
3.6
V
+10.5
+10
V
+10.5
+10
mA
20.4
20
mA
20.4
20
Ignition protection
"nA" and "tb"
DANGER
End value
Max. value
0
+10
+10.5
+10
+10.5
0
20
20.4
4
20
20.4
0
−0.5
−10
−10.5
0
4
3.6
english
End point
Error
value
+10.5
+10.5
20.4
3.6
−0.5
−10.5
0
20.4
3.6
17

Publicidad

Tabla de contenido
loading

Tabla de contenido