AVENTICS | CMS, BDC, Stand-Alone | R412008961–BDL–001–AF
6.5.4 Connection conditions for module
The external valves or valve systems are connected via
the plugs X201, X202, X203, X204.
Use pre-assembled plug connections and cables to
connect the modules.
O
Observe the pin assignment in Tab. 10 if you do not
use preassembled plug connections and cables.
Table 10:
Pin
X201
1
4
3
X202
1
4
3
X203
1
4
3
extension R412008692
Pin assignment of the plugs X201, X202,
X203, X204 for R412008692, 4x2 valve
outputs with M8 connection, 3-pin
Assignment
Valve output 2
Valve outputValve
output 1
0 V / ground for U
U
of the bus coupler
Q2
Valve output 4
Valve output 3
0 V / ground for U
U
of the bus coupler
Q2
Valve output 6
Valve output 5
0 V / ground for U
U
of the bus coupler
Q2
Assembly
Signal current
Max. 100 mA per
valve solenoid
Max. 100 mA per
valve solenoid
and
Q1
Max. 100 mA per
valve solenoid
Max. 100 mA per
valve solenoid
and
Q1
Max. 100 mA per
valve solenoid
Max. 100 mA per
valve solenoidper
valve solenoid
and
Q1
83
1)
1)
1)
1)
1)
1)