Possible Incidents; Operating Faults; Energy And Technical Features - Eurocave 6000 Serie Modo De Empleo

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 63
8 - O

Possible incidents

The
pictogram is displaying
The
pictogram is still displaying
even though I have taken the corrective
actions above
The
pictogram is displaying
The
pictogram is flashing
The appliance cannot lower the level of
humidity to the desired value
The
pictogram is displaying
The
pictogram is displaying
If your appliance does not seem to be working correctly, contact your EuroCave Professional retailer.
9 - E
6000
Height
1
mm
1 temperature
6182V
1825
6074V
960
2
temperatures
6170D
1825
Multi-temperatures
6182S
1825
6074S
960
Control accuracy: +/- 1°C (2°F), display accuracy: +/- 1°C (2°F).
1- Height including the top hinges and the feet, adjusted to mid-height.
2- Depth including a gap of 29 mm at the back of the cabinet for ventilation.
3- Electrical power per 24hrs measured with an external temperature of 25°C / 77°F and a solid door.
20
GB
N6000-0815-7L-V9.indd 20
PERATING FAULTS
Causes
The temperature has
not returned to within
the ±4 °C threshold
Operating fault
Open door alarm
The level of relative
humidity has been <
50 % for over 72 hrs
Charcoal filter alarm
Temperature sensor
fault alarm
NERGY AND TECHNICAL FEATURES
Width
Depth
2
Weight when empty
mm
mm
Full Glass door
(Kg)
680
690
96
680
690
60
680
690
100
680
690
94
680
690
58
Corrective actions
Check that the door is correctly closed.
Check the condition of the door seal.
If you placed a large amount of bottles in your cabinet in the last few hours,
wait a while then check again. If the alarm is still displaying, contact your
EuroCave Professional retailer.
Unplug the cabinet and contact your EuroCave Professional retailer.
Make sure that the door is correctly closed.
• Pour a glass of water into the duct of the tray (see chapter 7, § IV).
• In order to know how often to add water, count the number of days
separating the 1st day you added water and the day when the pictogram was
displayed
After a few hours, the pictogram will disappear.
• Empty the cabinet, remove the humidity cartridge and clean the tray.
• Remove the tube placed at the back of the tray. The humidity will be directly
discharged out of the appliance.
Call the EuroCave Professional retailer if the problem persists despite having
carried out these different operations.
Replace the charcoal filter (see chapter 4).
Contact your EuroCave Professional retailer.
Electrical power
Glass door (Kg)
Solid door (Kg)
230V-50Hz
(R600a gas)
94
89
58
56
98
93
92
87
56
54
The use of glass doors can alter your wine cabinet's performance
in some extreme temperature conditions.
3
Recommended
(Watts)
temperature range
Min T°(°C / °F) - Max T° (°C / °F)
115V-60Hz
Glass
(R134a gas)
75
105
0-30 / 32-86
65
95
0-30 / 32-86
65
95
10-30 / 50-86
75
105
12-30 / 54-86
70
95
12-30 / 54-86
Solid door
0-35 / 32-95
0-35 / 32-95
10-35 / 50-95
12-30 / 54-86
12-30 / 54-86
18/09/15 11:48

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

6182v6074v6170d6182s6074s

Tabla de contenido