ELECTRICAL CONNECTION

The boiler is supplied with an electric cable.
Should this require replacement, it must be
purchased exclusively from SIME.
The electric power supply to the boiler must
be 230V - 50Hz single-phase through a
fused main switch, with at least 3 mm spa-
cing between contacts.
Respect the L and N polarities and the
earth connection.
NOTE: SIME declines all responsibility for
injury or damage to persons, animals or
things, resulting from the failure to provi-
de for proper earthing of the appliance.
2. 1 1. 1
Chronothermostat connection
Connect the chronothermostat as indica-
ted in the boiler electrical diagram (see fig.
12 and 12/a) after having removed the
existing bridge.
The chronothermostat to be used must be
of a class conforming to the standard EN
2. 1 1.5 Use with different
electronic systems
Some examples are given below of boiler
systems combined with different electronic
systems. Where necessary, the parame-
ters to be set in the boiler are given.
The electrical connections to the boiler
refer to the wording on the diagrams (see
fig. 12 and 12/a).
Zone valve control is activated with every
heating request from remote control.
Description of the letters indicating the
components shown on the system dia-
grams from 1 to 7:
M
C.H. flow
R
C.H. return
CR
Remote control CR 63
SE
External temperature sensor
TA 1-2 Zone room thermostat
VZ 1-2 Zone valve
RL 1-2 Zone relay
Sl
Hydraulic separator
P 1-2
Zone pump
SB
D.H.W. sensor
IP
Floor system
EXP
Expansion card
(code 8092240)
VM
Three-way mixer valve
TSB
Safety thermostat low
temperature
100
607301 (clean electrical contact).
2. 1 1.2 Climatic regulator CR 63
connection (optional)
The boiler is designed for connection to a
remote control unit CR 63 code 8092219
coupled to an optional expansion kit code
8092240.
The remote control CR 63 unit allows for
complete remote control of the boiler,
except release of the boiler.
Whenn the connection has been made the
boiler display will show the following messa-
ge: Cr.
For installation and use of the remote con-
trol, follow the instructions in the package.
2. 1 1.3 External sensor
connection (optional)
The boiler is designed for connection to an
external temperature sensor, supplied on
request (code 8094101), which can auto-
1
BASIC SYSTEM
SYSTEM WITH A DIRECT ZONE AND ROOM THERMOSTAT, OR WITH
A REMOTE CONTROL (Code 8092219), KIT EXPANSION REMOTE
CONTROL (Code 8092240) AND EXTERNAL SENSOR (Code
8094101)
SE
R
TA
matically regulate the temperature value of
the boiler output according to the external
temperature.
For installation, follow the instruction in the
package.
It is possible to make corrections to the
values read by the drill acting on the PAR 4.
2. 1 1.4 D.H.W. sensor connection
vers. "12 T"
The "12 T" version is provided with a
D.H.W. sensor (SB) linked to the connector
CN5. When the boiler is coupled to an
external boiling unit, introduce the sensor
into the special sleeve in the boiling unit.
ATTENTION: The "12 T" version is desi-
gned for connection to a remote boiling
unit, for use ONLY FOR HEATING it is
necessary:
- to disconnect the D.H.W. sensor (SB);
- set PAR 2 = 4.
Operations must be carried out by autho-
rized and qualified technicians.