Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

UK
This solution provides a product that is easy to use, easy to install and highly versatile. The use of leading edge technology has
allowed the machine's dimensions to be optimized, improving the installation method, especially on cells with reduced sizes.
The FS line is available in two different versions: a nitrogen loaded machine with tap attachments for all models or, where available,
with refrigerant gas loaded and quick connections; in this case pre-loaded connection piping can be requested.
The models use the following codes:
FS = with nitrogen load and tap attachments
FS/R = with refrigerant gas load, quick connections and piping kit in 2.5/5/10 m lengths.
The FS model is a split Blocksystem with wall mounting for the refrigeration of cells from 1/3 HP to 3 HP.

2.1. Control panel

Below (Table 2) reports the description of the commands on the management software.
Figure 1 Control panel
Table 2 – commands descriptions.
SIMBOL
Green "COMPRESSOR" LED
OFF: The compressor is off
LIT: The compressor is operating.
BLINKING: The switch on request is pending (delays or protective devices activated)
Green "FANS" LED
OFF: The fans are off
LIT: The fans are operating
BLINKING: The switch on request is pending (delays or protective devices activated)
Green "DEFROSTING" LED
OFF: Defrosting is not activated
LIT: Defrosting is in progress
BLINKING: Manual defrosting is in progress; a defrosting request is pending (delays or protective devices activated);
network synchronised (master/slave) defrosting
Yellow "ALARM LED"
OFF: No alarm is in progress
LIT: A serious alarm is in progress (and alarm relay activated)
BLINKING: A non-serious alarm is in progress or a serious alarm has been silenced (alarm relay deactivated)
"SETPOINT" key + "SETPOINT/REDUCED SET" green LED
LIT: The setpoint is displayed
BLINKING: The reduced set is activated
ENTER" key: This is used to set the setpoint, to access the programming menu, and to view the machine status (if held
down for 1 second); to enter the programming mode, this key must be held down for 5 seconds.
"UP" key: This is used to command manual defrosting (if held down for more than 5 seconds) as well as to increase
the value of the parameter being displayed and to scroll forwards through the menu list.
set
on
off
DESCRIPTION