Recording measured values

1. Call up the "Report" selection menu with <F2>.
2. Select the "Restart test" menu.
3. Call up the "Meas. funcs." selection menu with <F7>.
4. Select the "Automatic on/off" menu item and
activate the automatic mode function with <F12>.
 The automatic mode symbol flashes in the
operating status display.
 The specified values are set and the waiting/mea-
surement time commences. On completion of the
waiting/measurement time, the software switch-
es automatically to the next test step.
5. In the event of the message "
further test step! Results with F12
>>.
", call up the protocol with <F12>.
6. Print out the protocol with <F3> and "Print" (for filing).
i
If print-out is not possible, note down the measured
values on a sheet of paper.
7.8

Saving calibration values

1. Exit from the "Result printout" dialog window
with <Esc>.
2. In the "Injection component - test main menu" start
screen select <F7>.
 A password request appears.
3. Enter the password in the input line:
4. Confirm the entry with <F12>.
5. Select the menu item Calibration >> Rail pressure
sensor.
 The measured values obtained in Section 7.7
have automatically been entered in the boxes for
Test bench pressure value, Test bench press.val.
upst.of filter and External pressure value.
6. Save with <F4>.
"
The calibration date is updated.
Robert Bosch GmbH
System stop! No
1958
Calibrating high-pressure rail | EPS 708 | 47
7.9

Starting checking

1. In the "Rail pressure sensor calibration" window,
select <F6>.
 Calibration value checking is active.
2. Save the entry with <F12>.
3. Exit from the menu with <Esc>.
 The software performs re-initialization
of the devices.
4. In the "Injection component test - main menu" start
screen select <F12>.
 Displaying legal information. (Page 1 of 2)
5. Read legal information carefully and adhere to under
all circumstances.
6. Continue with <F12>.
 Displaying legal information. (Page 2 of 2)
7. Read legal information carefully and adhere to under
all circumstances.
8. Continue with <F12>.
9. Call up the "Database" selection menu with <F2>.
10. Select the "New component" menu with <F12>.
11. In the "Type number" box, enter the numbers
0445020105
.
12. Call up the "Database" selection menu with <F2>.
13. Select the "Search for component" menu with <F12>.
 The "Component selection Local database"
window is displayed.
14. Select the test procedure for pressure sensor
checking 0445020105 C1 and call up with <F12>.
15. Call up the "Measurement display" window
with <F12>.
 The "Attention" dialog box opens with the maxi-
mum speed.
16. Continue with <F12>.
17. Start pump testing with <F8>.
 The EPS 708 drive starts up.
"
The test bench is ready for operation.