3. Use a suitable lifting harness that is mounted in the interior of the fan component (Pos.
7) to lift the fan component (Pos. 3) from the pallet (Pos. 8) and set it down at the
installation location.
4. Remove the start-up protection (Pos. 4) by loosening the screws all round. Then it can
be taken off outwards.
5. The floor plate of the fan component (Pos. 3) has eight fastening holes to anchor the
product securely to the hall floor. Use suitable fixing material for anchoring.
1502828-01
Fig. 25: Positioning the fan component
Fig. 26:
- 63 -