To do so, proceed as follows:
1. Switch off the product using the on/off switch and wait until the illuminated ring on
the on/off switch stops flashing completely.
2. Disconnect the product from the power supply by pulling out the mains plug and
secure against unintentional restarting.
3. Remove the rear service cover of the fan component.
4. If necessary, the pressure for the compressed air container must be readjusted to 5 bar
on the pressure regulator (Pos. 1).
5. Connect the product to the power supply and press the on/off switch to put it back
into operation. See also the chapter Commissioning.
7.2.4 Checking the compressed air container with compressed air safety
valve
NOTE
The product has one or more compressed air containers with compressed air safety
valve.
Products with compressed air container and safety valve must be serviced/checked
according to current national regulations.
1502828-01
Fig. 37: Setting the compressed air regulator
- 78 -