Troubleshooting - Kemper CleanAirTower Instrucciones De Servicio

Ocultar thumbs Ver también para CleanAirTower:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 171

7.3 Troubleshooting

Fault
Green illuminated ring around
the on/off switch does not
light up
Product does not start
Yellow signal lamp flashes at
regular intervals
Yellow signal lamp flashes
briefly twice at regular
intervals
Yellow signal lamp flashes
briefly four times at regular
intervals
Yellow signal lamp flashes
briefly five times at regular
intervals
Yellow signal lamp flashes
briefly six times at regular
intervals
Yellow signal lamp flashes
briefly seven times at regular
intervals
Signal horn sounds
Dust escapes on the clean air
side
NOTE
If the fault cannot be corrected by the customer, please contact the manufacturer's
service department.
1502828-01
Cause
No power supply available
No power supply available
Product maintenance is due Contact the
The frequency converter
has a fault
Compressed air error
Control error
Control error
Cleaning not successful
Flow resistance too high.
Filter inserts soiled
Filter inserts damaged
Tab. 23: Troubleshooting
- 79 -
Note
Have the power supply
checked by a qualified
electrician
Have the power supply
checked by a qualified
electrician
manufacturer's service
department
Switch product off for
approx. 30 sec. – Restart,
contact manufacturer's
service department
Check compressed air
supply
Contact the
manufacturer's service
department
Contact the
manufacturer's service
department
Check solenoid valve,
check plug connections,
check solenoid valve cable
Change filter inserts –
Contact manufacturer's
service department
Change filter inserts –
Contact manufacturer's
service department
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido