Initial startup

For the figures, refer to the graphics page
ATTENTION
Electrical shock in the event of a short-
circuit
Exceeding the mains grid impedance can
cause a short-circuit.
The maximum permissible mains grid im-
pedance at the electrical connection point
(see Technical data) must not be exceed-
ed.
DANGER
Damage to the skin, lungs and eyes
through fine dust
Emission of fine dust when used without a
filter or with a damaged filter
Never vacuum without a filter or with a
damaged filter.
ATTENTION
Damage to the device
The suction motor can be damaged if the
device is used without a filter or with a dam-
aged filter.
Never vacuum without a filter or with a
damaged filter.
1. Bring the device into the working posi-
tion and secure with the parking brake if
necessary.
2. Ensure that the suction head is fitted
correctly.
3. Insert the suction hose into the suction
hose connection.
Illustration B
4. Plug the desired accessory onto the suc-
tion hose.
5. Check the filling level of the dirt recepta-
cle and empty it if necessary before
starting vacuuming.

Operation

Switching on the device

For the figures, refer to the graphics page
If the main switch springs back to position 0
when the device is switched on then the po-
larity at the unit plug is incorrect. Change
the polarity at the unit plug.
A plug with phase inversion is not permitted
in zone 22.
1. Connect the mains plug.
2. Switch on the device at the main switch.
Illustration C
Wet vacuum cleaning operation
ATTENTION
Risk of damage if the dirt receptacle
overflows
The dirt receptacle can fill within a few sec-
onds and overflow when vacuuming large
amounts of liquids.
Continuously monitor the filling level.
1. Perform vacuuming.
2. Regularly check the filling level in the dirt
receptacle.
3. Empty the vacuum cleaner waste con-
tainer as necessary.
4. Clean or replace the filter as necessary.
Dry vacuuming operation
DANGER
Damage to the skin, lungs and eyes
through fine dust
Expulsion of fine dust due to a filter that is
no longer permissible
If the device has previously been used for
wet vacuum cleaning, the filter used for this
(wet or dried) is no longer suitable for dry
vacuuming.
Replace the filter with a new, dry filter.
1. Perform vacuuming.
2. Clean or replace the filter as necessary.

Cleaning the filter

A pressure gauge showing the vacuum in-
side the device is mounted on the front of
the device. If the vacuum is greater than the
value specified in the table, then the filter
must be cleaned/replaced.
IVS 100 / 55
IVS 100 / 75
1 Switch off the device at the "ON/OFF
switch".
English
NW 42
NW 52 NW 72
19.5 kPA 18 kPA 10 kPA
28 kPA
24 kPA 13 kPA
15