IO-Link Data Dictionary
21.10.01.00065/02
EPC Data Buffer - Details
Data Format of Single Entry (ISDU 134)
Bytes 0...1
Bytes 2...3
Evacuation time t1 (MSB first)
Leakage rate (MSB first)
Data Format of EPC Data Buffer (ISDU 133)
Bytes 0...9
Bytes 10...19
Bytes 20...29
Entry 1 (newest)
Entry 2
Entry 3
Implemented IO-Link Events
Event code
Event name
0x1000
General malfunction
0x5100
General power supply fault
0x5110
Primary supply voltage over-run
0x8C01
Simulation active
0x1800
Vacuum calibration OK
0x1801
Vacuum calibration failed
0x1802
System pressure fault
J. Schmalz GmbH
Bytes 4...5
Bytes 6...9
Free-flow vacuum (MSB first)
Counter cc1 (MSB first)
...
...
Event type
Remark
Error
Internal error e.g. E01 / E02
Error
Primary supply voltage US too low
Warning
Primary supply voltage US too high
Warning
Manual mode active
Notification
Notification
Warning
System pressure outside of operating range
11 of 11
J. Schmalz GmbH
Aacher Straße 29, D 72293 Glatten
Tel.: +49(0)7443/2403-0
Fax: +49(0)7443/2403-259
info@schmalz.de
Remark
Counter value cc1 of when the data was recorded
Bytes 90...99
Remark
Entry 10 (oldest)
Buffer of 10 entries (newest to oldest) with encoding as in ISDU 133
SCPSi series
29.08.2014
SCPSi Data Dictionary