Connecting the control signal cable
(Use a twisted-pair cable for connection.
Camera 1
control signal
connection terminals
+
TX
A
TX
B
+
RX
C
RX
D
Camera 2
control signal
connection terminals
+
TX
A
TX
B
+
RX
C
RX
D
Setting the switches (
SET
CAMERA
SETUP
EXT TERM-OFF
ON
AWC
MENU
LL
INT/GL
DUPLEX
SIMPLEX
RX TERM-OFF
ON
NOT USED
VIDEO
DC
Setting on the MENU screen (
* If the setting is changed, escape from the menu screen once, and definitely switch on the power again.
C O
S T L E
Y
MA H NE
C
I
When connecting
● Turn OFF the power supply to all equipment to be used before making connections.
● Carefully read the Instructions for each piece of equipment to be used before making
connections.
● For the appropriate connection cables and the length of these, carefully read "Connections
on the back" on page 16.
● The control signal cable cannot be used for loop connection.
RM-P2580
A RX
B RX
C TX
D TX
Page 10)
EXT TERM-OFF
INT/GL
DUPLEX
RX TERM-OFF
NOT USED
IRIS
MM
UN I C A T I O N
M . DROP
I
D
1
Page 17.)
Connect:
+
Camera TX+ to RM-P2580 RX+
Camera TX– to RM-P2580 RX–
+
Camera RX+ to RM-P2580 TX+
Camera RX– to RM-P2580 TX–
The A B C D marks indicated on both the
camera terminals and the RM-P2580 termi-
nals facilitate correct connections. Connect
the terminals with identical marks.
Select the synchronization method of the
camera image.
Set the switch on all cameras to LL (Line Lock)
and match with the V. PHASE.
(
Page 26.)
ON
Set this switch to the DUPLEX
LL
* If the setting is changed, be absolutely sure to
SIMPLEX
ON
switch on the power again.
Set this switch to ON (signal termination ON)
only on the camera placed at the end of the
control signal cable.
Set to OFF on all other cameras.
Page 33)
Set to M.DROP
Set to M.DROP when the RM-P2580 is used
as a remote control unit. When controlling
from another machine, make sure that it
matches the communication system used.
MACHINE ID setting switches
Set this item to match the RM-P2580 VIDEO
INPUT terminal number for each camera.
E-13