Mimic panel
to turn on and off (hold down for 2") and to exit from the menu during programming
to access the menu during programming
to increase the various settings
to decrease the various settings
(pellet loading/reserve button)
press once to 'inform' the boiler memory that a 15 kg sack of pellets has been loaded, thereby allowing it to keep track
of the reserve.
(boiler setting button)
this button together with the +/- keys controls a secondary circuit, e.g. that of a boiler.
The right side of the display shows the temperature of any external storage tank/boiler (if the boiler sensor is con-
nected). Press the 'boiler' button to see the set value. If the boiler sensor is not connected, dashes will appear instead of
the temperature (--- °C).
Left display
Filling the feed screw
If the pellet storage tank is completely emptied, it follows that
the Archimedes' screw is also emptied.
Before restarting the boiler you must fi ll it by following these
steps:
press the +/- keys simultaneously for a few seconds, after
which, having released the keys, the display will show the text
"Reload".
It is quite normal for some pellet residue to remain inside the
hopper, this is what the feed screw is unable to pick up.
Once a month, fully vacuum the hopper to prevent dusty resi-
due from accumulating.
Automatic ignition
With the boiler on stand-by, press the 0/1 button for 2 seconds.
This will start-up the ignition process, 'Start' will appear on
the display and a countdown will commence in seconds (1020).
There is no preset time for the ignition process:
its duration will be automatically shortened if the control board
detects that certain tests have been carried out positively.
The fl ame appears after about 5 minutes.
INSTRUCTIONS FOR USE
Pellet load/reserve
- 38
Boiler
Right display
Manual ignition (in case of start up failure)
At a temperature lower than 3 °C too low for the electrical resi-
stance to become red hot or if the resistance is temporarily not
working, you can use a fi relighter to ignite the boiler.
Insert a well-lit fi relighter into the combustion chamber, close
the door and press 0/1 on the synoptic panel.
Operating modes
With the boiler running or on stand-by, from the synoptic
panel:
- press the + or – keys to increase or decrease the desired water
temperature.
- by pressing the key you can change the SET temperature of
the boiler or of the secondary circuit in general, using the +/-
keys.
It is possible to visualise (if the boiler probe is connected) the
temperature of any boiler/external storage, by pressing the
"boiler" key the set value is displayed, by pressing the +/- keys
while viewing the boiler value set that setting can be varied.
If the boiler probe is not connected dashes appear in place of
the temperature (--.-° C).
-