MAINTENANCE
Before performing any maintenance, disconnect the appliance from the mains.
FAILURE TO PERFORM REGULAR MAINTENANCE, at least on a seasonal basis, could lead to poor functionality.
Any problems resulting from lack of maintenance will immediately void the warranty.
WEEKLY CLEANING
(see illustration on next page)
Cleaning should be carried out with the aid of a vacuum cleaner (see optional page. 45).
Operation to be carried out when the boiler is cold.
Never vacuum hot ashes, as this would damage your vacuum cleaner.
• Suction clean the door.
• Open the small door and remove and empty the ash tray (Fig. A-1) vacuum the fi re bed.
• Remove the front tile (Fig. B-2).
• Vacuum the crucible or scrape it with the spatula provided, clear any obstructions from the holes on all sides, after removing the
front plate (fi g. C -3).
• Clean the spark plug
• Remove the inspection plugs on both sides of the hearth and vacuum the crucible (Fig. D-4).
• Move the swabs (*) by moving the lever from the top down (see fi g. E) after having removed it from its housing.
• Following a period in which the boiler has been inactive and in any case at least every month, empty the pellet storage tank and
vacuum the bottom.
NEVER VACUUM HOT ASH, it can make the vacuum cleaner breakdown and puts the household rooms at risk of fi re.
SEASONAL CLEANING
(implemented by the dealer)
The Dealer will provide you, on the occasion of the fi rst start up, with the stove maintenance book, where the steps for
seasonal cleaning, outlined here below, are listed.
• Clean the boiler internally and externally
• Carefully clean the heat exchange tubes
• Carefully clean and remove dirt from the combustion chamber and the relative compartment
• Clean the motors, verify mechanical and clam loosening
• Clean smoke channel (replace seals on pipes) and smoke extraction fan chamber
• Check the expansion tank
• Check and clean the circulator
• Check the sensors
• Check and if necessary replace the clock battery on the control board
• Clean, inspect and scrape any residue from the ignition resistance compartment and if necessary, replace it
• Clean/check the Synoptic Panel
• Visually inspect the electrical wires, connections and power cable
• Clean the pellet hopper and check loosening of the feed screw - gear motor assembly
• Check and if necessary replace the door seal
• Functionality test: load the feed screw, ignite, let it run for 10 minutes and shutdown
If maintenance if not implemented, the warranty will be rendered null and void.
If the boiler is used very often, it is recommended to clean the smoke channel every 3 months.
When maintenance is implemented in the smoke channel, consider UNI 10847/2000 Individual chimney installations for
generators running on liquid and solid fuel. Maintenance and control.
The chimney stacks and smoke ducts to which solid fuel appliances are connected should be cleaned once a year (verify
whether in there are regulations in force in your country regarding this).
In the even that regular checks and cleaning are not performed the probability of a chimney fi re increases.
In the event of such an occurrence proceed as follows:
- do not extinguish with water
- empty the pellet storage tank
- contact the Dealer before re-starting after such an incident.