Description; Display/Operating Elements; Inputs; Inp A, Inp B - Kübler CODIX 923 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

3

Description

6-digit multifunction LCD display
Easy-to-read 2-line LCD display with annunciators
for both the displayed preset and the status of the
output
Simultaneous display of the actual value and of the
preset or auxiliary counters
Versions with/without backlit display
Add./Sub. Preset counter with one preset
Relay output
Easy-to-program
Simple preset entry via the front keys or via the
Teach-In function
Pulse, frequency, time or hours run meter
Preset counter, Batch counter or Total Counter
(cumulative count)
Set function for pulse and time counter
Multiplication and division factor (00.0001 ..
99.9999) for pulse counter and frequency meter
Averaging and Start Delay for frequency meter
Input modes:
Pulse counter: cnt.dir , up.dn , up.up , quad ,
quad2 , quad4 , A/B , (A-B)/Ax100%
Frequency meter: A , A – B , A + B , quad , A/B ,
(A-B)/Ax100%
Timer: FrErun , Auto , InpA.InpB , InpB.InpB
Output operations:
Add , Sub , AddAr, SubAr , AddBat , SubBat ,
AddTot
4-stage RESET-Mode
3-stage keypad locking (Lock)
MPI input for Display Latch, Teach-In function or
Set function
Supply voltage 90 .. 260 VAC or
10 .. 30 VDC
4

Display/Operating elements

www.kuebler.com
T1-6 Decade key T1 ... T6
Prog/Mode key
P
R Reset key
8
Current count value / main counter
9
Preset value/ Total count/ Batch counter
10 Run display for Timer
11 Indicator for preset value in the display
12 Indicator for active preset output
Keys necessary for programming the
Pr
parameters (highlighted in grey)
5

Inputs

5.1

INP A, INP B

Signal inputs: function acc. to operating mode.
Max. frequency 60 kHz, can be damped in the
programming menu to 30 Hz.
Pulse counter:
Count inputs
Frequency meter:
Frequency inputs
Timer:
Start input or
Start/Stop inputs
5.2

RESET

Dynamic reset input: resets the pulse counter or
timer to zero (adding mode) or to the preset value
(subtracting mode). The reset input can be inhibited
in the programming menu.
Pulse counter:
RESET input
Frequency meter:
no function
Timer:
RESET input
5.3

GATE

Static gate input: function depending on operating
mode.
Pulse counter:
no counting while active
Frequency meter:
no counting while active
Timer:
no time measurement while
active(Gate.hi)
no time measurement while
not active (Gate.Lo).
5.4

LOCK INPUT

Static keypad lock input for preset or programming.
Lock-out level can be set in the programming
menu.
5.5

MPI

Input. Programmable as Display Latch, Set or
Teach-In input.
Page 5