ADD mode output operations:
timed signal at the output,
becomes active with positive
direction and when count >
preset and subsequently active
with negative direction and when
count < preset
SUB mode output operations:
timed signal at output, becomes
active with negative direction and
when count < 0 and
subsequently active with positive
direction and when count > 0
ADD mode output operations:
timed signal at the output,
becomes passive with positive
direction and when count >
preset and subsequently passive
with negative direction and when
count < preset
SUB mode output operations:
timed signal at the output,
becomes passive with negative
direction and when count < 0 and
subsequently passive with
positive direction and when count
> 0
Duration of timed signal,
programmable from 00.01 to
99.99 s.
Timed signal is post-triggered
Active:
Relay is activated when the
preset value is reached.
Passive:
Relay is de-energized when the
preset value is reached.
7.9

Setting the preset

7.9.1 Setting via Decade Keys

In the operating mode, the preset value will always
be displayed in the lower line. This is except for the
output operations AddBat, SubBat and AddTot.
Press the Prog/Mode key until
the preset to be changed is
displayed -
Press any decade key
Display switches to the editor mode
Page 14
Set the desired preset value
using the decade keys
Approx. 3 s after the last press of
the decade keys or by pressing
the Reset key the new preset
value will be accepted and the
counter will switch back to
operating mode.

7.9.2 Setting with Teach-In Function

Program the MPI input to tEAch
In programming mode, select the
preset to be changed using the
Prog/Mode key
Briefly activate the MPI (NPN or PNP input logic)
The current count value will be adopted as
the new preset value
The preset value can subsequently be
further modified via the decade keypad.
7.10

Set Function

Both the pulse counter and the timer can be set to
a default value by means of the Set function.
Program the MPI input to SEt
Set menu item SEtPt to the
desired value
Briefly activate the MPI (NPN or PNP input logic)
For add. output operations the pulse
counter or timer will be set to the SEtPt
default value
For sub. output operations the pulse
counter or timer will be set to the amount
between the value of Preset 2 and the
value of SEtPt .
8

Error message

Err 1
Set value is outside the permitted range
www.kuebler.com