6

Output

6.1
Output
Relay with potential-free changeover contact
6.2

Active Output

The active output will be shown on the display as
.
For safety switching the relay output can be
inverted, i.e. the relay will be de-energized when
the preset is reached.
To do this, the parameter Pr.OUT1 must be set to
(for permanent signal) or
timed signal).
7

Programming

7.1

Entering the programming

Press the Reset key and
Prog/Mode key simultaneously
for 3 s
Programming can be exited
again using the Prog/Mode key.
Press key T2 to continue with the
programming
Enter the main menu by pressing
the Prog/Mode key
7.2

Choice of main menus

The menus are selected using
the keys T2 (next) and T1 (back)
7.3

Entering a sub-menu

The sub-menu is opened with the
Prog/Mode key and the first
menu item is displayed.
Page 6
or
(for
The security prompt
appears in the display
The security prompt
appears in the display
7.4

Selecting the menu items

The Prog/Mode key is used to
select a menu item within the
sub-menu
7.5

Setting the menu items

The T2 key is used to select the
individual settings for the menu
items
When setting count values, each
decade has a key assigned to it.
Each time the key is pressed,
the value increments by one
7.6

Accepting the setting

Pressing the Prog/Mode key
causes the current setting to be
accepted. Programming then
switches to the next menu item.
7.7

Ending the programming

During programming, it is possible to exit the
programming at each menu item by pressing the
reset key.
Press the Reset key
Pressing the Prog/Mode key
acknowledges this prompt and
causes the programming menu
to start again from the beginning.
The previously-programmed
values are preserved. These can
now be changed or checked
again.
Pressing the decade key T2
selects the termination of the
programming
Pressing the Prog/Mode key
acknowledges this prompt and
terminates the programming; the
modified settings are saved in
the EEPROM.
The security prompt
appears in the display
The security prompt
appears in the display